LATTICE-PARAMETER MEASUREMENT OF GAAS CRYSTALS USING MONOCHROMATIC SYNCHROTRON RADIATION

被引:10
作者
USUDA, K [1 ]
YASUAMI, S [1 ]
HIGASHI, Y [1 ]
KAWATA, H [1 ]
ANDO, M [1 ]
机构
[1] NATL LAB HIGH ENERGY PHYS,TSUKUBA,IBARAKI 305,JAPAN
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS | 1990年 / 29卷 / 02期
关键词
Composition; Crystal; Diffractometer; GaAs; Lattice parameter; Monochromator; Synchrotron radiation;
D O I
10.1143/JJAP.29.L210
中图分类号
O59 [应用物理学];
学科分类号
摘要
A high-resolution diffractometer with a monolithic Si monochromator was developed for lattice parameter (d) measurements using synchrotron radiation. The accuracy attained was 5.9×10-6in terms of Δd/d. This degree of accuracy makes it possible to discuss the lattice parameter variation due to composition shifts in GaAs crystals. However, a preliminary study implied that thermally-induced elastic strain affects the lattice parameter more than the material composition shifts for crystals with the 104∼105cm-2order of dislocation density. © 1990 IOP Publishing Ltd.
引用
收藏
页码:L210 / L212
页数:3
相关论文
共 50 条
  • [1] Bunch length measurement using spectral width of monochromatic synchrotron radiation
    Ogata, A.
    Kondoh, T.
    Yang, J.
    Yoshida, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (01) : 348 - 350
  • [2] Precision d-spacing measurement of GaAs single crystals with synchrotron radiation
    Okada, Y
    Zhang, X
    Sugiyama, H
    Imai, Y
    Rahman, MO
    Higashi, Y
    Nakayama, K
    Fujimoto, H
    Yoda, Y
    Ando, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1037 - 1040
  • [3] Operando measurement of lattice deformation profiles of synchrotron radiation monochromator
    Zhang, Yue
    Li, Zhong-Liang
    Si, Shang-Yu
    Xue, Lian
    Luo, Hong-Xin
    Zhang, Xiao-Wei
    Hu, Jun
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (07)
  • [4] In Situ Observation of Recrystallization of Aluminum Single Crystals Using Synchrotron Radiation Monochromatic X-Rays
    Shiro A.
    Shobu T.
    Okada T.
    Zairyo/Journal of the Society of Materials Science, Japan, 2022, 71 (04): : 354 - 360
  • [5] Testing the relative deformation of the lattice parameter of semiinsulating GaAs using reflected radiation
    D. I. Bilenko
    O. Ya. Belobrovaya
    V. G. Lyubivyi
    D. V. Terin
    Russian Journal of Nondestructive Testing, 2004, 40 (8) : 565 - 568
  • [6] Testing the relative deformation of the lattice parameter of semiinsulating GaAs using reflected radiation
    D. I. Bilenko
    O. Ya. Belobrovaya
    V. G. Lyubivyi
    D. V. Terin
    Russian Journal of Nondestructive Testing, 2004, 40 (8) : 565 - 568
  • [7] PHOTOCHEMICAL ETCHING OF GAAS USING SYNCHROTRON RADIATION
    TERAKADO, S
    NISHINO, J
    MORIGAMI, M
    HARADA, M
    SUZUKI, S
    TANAKA, K
    CHIKAWA, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1990, 29 (05): : L709 - L711
  • [8] Characterization of HAPG mosaic crystals using synchrotron radiation
    Gerlach, Martin
    Anklamm, Lars
    Antonov, Alexander
    Grigorieva, Inna
    Holfelder, Ina
    Kanngiesser, Birgit
    Legall, Herbert
    Malzer, Wolfgang
    Schlesiger, Christopher
    Beckhoff, Burkhard
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2015, 48 : 1381 - 1390
  • [9] Throughput measurement of a multilayer-coated Schwarzschild objective using synchrotron radiation
    Kiyokura, T
    Maeda, F
    Watanabe, Y
    Iketaki, Y
    Nagai, K
    Horikawa, Y
    Oshima, M
    Shigemasa, E
    Yagishita, A
    OPTICAL REVIEW, 2000, 7 (06) : 576 - 578
  • [10] Development of cryogenic tensile testing apparatus for lattice strain measurement using synchrotron radiation for REBCO composite conductors
    Sugano, Michinaka
    Machiya, Shutaro
    Shobu, Takahisa
    Shiro, Ayumi
    Kajiwara, Kentaro
    Nakamoto, Tatsushi
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2020, 33 (08)