DETERMINATION OF TOTAL AMMONIUM-NITROGEN AND FREE AMMONIA IN A FERMENTATION MEDIUM BY SEQUENTIAL INJECTION-ANALYSIS

被引:32
作者
LUKKARI, I
RUZICKA, J
CHRISTIAN, GD
机构
[1] UNIV WASHINGTON,DEPT CHEM BG10,SEATTLE,WA 98195
[2] UMEA UNIV,DEPT ANALYT CHEM,S-90187 UMEA,SWEDEN
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1993年 / 346卷 / 6-9期
关键词
D O I
10.1007/BF00321296
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Automated methods for the determination of ammonium and anmonia are reviewed, and techniques based on gas diffusion using a semi-permeable membrane were selected for the determination of both total ammonium-nitrogen and free ammonia in fermentation samples. A simple and robust instrument based on sequential injection analysis (SIA) consisting of a piston pump and two selector valves was used. Two different methods of ammonia detection, the Berthelot method and detection using pH-indicators, have been evaluated and compared. The indicator method showed higher reproducibility and the range of determination could easily be adjusted to match the concentrations of the samples. The range of determination could be adjusted from 0.05 mmol/l to 350 mmol/l, depending on choice of acceptor solution. This method has been evaluated with fermentation medium samples and tested on-line in a yeast fermentation process.
引用
收藏
页码:813 / 818
页数:6
相关论文
共 23 条
[1]   CONTINUOUS-FLOW FLUOROMETRIC-DETERMINATION OF AMMONIA IN WATER [J].
AOKI, T ;
UEMURA, S ;
MUNEMORI, M .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :1620-1622
[2]   MONITORING OF SUBSTRATES AND PRODUCTS DURING FED-BATCH PENICILLIN FERMENTATIONS ON COMPLEX MEDIA [J].
CHRISTENSEN, LH ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :123-136
[3]   NOVEL FLOW-INJECTION ANALYSIS METHOD FOR BIOPROCESS MONITORING [J].
CHUNG, S ;
WEN, XW ;
VILHOLM, K ;
DEBANG, M ;
CHRISTIAN, G ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1991, 249 (01) :77-85
[4]   AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF AMMONIA [J].
CLINCH, JR ;
WORSFOLD, PJ ;
SWEETING, FW .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :401-407
[5]  
COSANO JS, 1988, ANAL CHIM ACT A, V221, P173
[6]  
DEBAND M, 1992, COMMUNICATION
[7]   COMPARISON OF THE POWELL AND SIMPLEX METHODS IN THE OPTIMIZATION OF FLOW-INJECTION SYSTEMS - SIMULATION ON MODELED EXPERIMENTAL SURFACES AND EXPERIMENTAL OPTIMIZATIONS [J].
DELVALLE, M ;
POCH, M ;
ALONSO, J ;
BARTROLI, J .
ANALYTICA CHIMICA ACTA, 1990, 241 (01) :31-42
[8]  
GAM M, 1989, BIOTECHNOL BIOENG, V34, P423
[9]  
GENFA Z, 1989, Analytical Chemistry, V61, P408, DOI 10.1021/ac00180a006
[10]   DETERMINATION OF AMMONIUM ION BY FLUOROMETRY OR SPECTROPHOTOMETRY AFTER ONLINE DERIVATIZATION WITH ORTHO-PHTHALALDEHYDE [J].
GOYAL, SS ;
RAINS, DW ;
HUFFAKER, RC .
ANALYTICAL CHEMISTRY, 1988, 60 (02) :175-179