Review on Cooling System Energy Consumption in Internet Data Centers

被引:8
作者
Amoabeng, Kofi Owura [1 ]
Choi, Jong Min [2 ]
机构
[1] Hanbat Natl Univ, Grad Sch Mech Engn, 125 Dongseodaero Yuseong Gu, Daejeon 305719, South Korea
[2] Hanbat Natl Univ, Dept Mech Engn, 125 Dongseodaero Yuseong Gu, Daejeon 305719, South Korea
关键词
Energy consumption; data center; cooling system; power usage effectiveness;
D O I
10.1142/S2010132516300081
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to the advancement of the telecommunication and information technology (IT) industry, internet data centers (IDCs) have become widespread in the public and private sectors. As such, energy demand in the center has also become increasingly prominent. Several technologies on energy management have been studied to determine the options available to minimize the energy required to operate the data center as well as reduce greenhouse gas emissions. The cooling system is required to remove the high heat dissipated by the IT electronic components especially the servers in order to ensure safe and reliable working condition. However, it utilizes more than one-third of the total energy consumption in the data center. In this study, the energy effciency technologies that are usually applied to cooling systems in data centers were reviewed. The aim is to find out the strategies that will reduce the energy consumption of the cooling system since the cooling demand in data center is all year round. Prior to that, the performance metric tool that is mostly used in analyzing data center effciency was discussed. The conventional cooling system technologies that are utilized in data centers were also provided. Lastly, innovative cooling technologies for future solutions in data centers were discussed.
引用
收藏
页数:17
相关论文
共 88 条
[11]   Air filter materials, outdoor ozone and building-related symptoms in the BASE study [J].
Buchanan, I. S. H. ;
Mendell, M. J. ;
Mirer, A. G. ;
Apte, M. G. .
INDOOR AIR, 2008, 18 (02) :144-155
[12]   Cooling systems in data centers: state of art and emerging technologies [J].
Capozzoli, Alfonso ;
Primiceri, Giulio .
SUSTAINABILITY IN ENERGY AND BUILDINGS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE SEB-15, 2015, 83 :484-493
[13]   Thermal metrics for data centers: a critical review [J].
Capozzoli, Alfonso ;
Serale, Gianluca ;
Liuzzo, Lucia ;
Chinnici, Marta .
6TH INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN ENERGY AND BUILDINGS, 2014, 62 :391-400
[14]   Review on Performance Metrics for Energy Efficiency in Data Center: The Role of Thermal Management [J].
Capozzoli, Alfonso ;
Chinnici, Marta ;
Perino, Marco ;
Serale, Gianluca .
ENERGY EFFICIENT DATA CENTERS (E2DC 2014), 2015, 8945 :135-151
[15]  
Chang Y. T., 2012, Patent US, Patent No. 8254122B2
[16]  
Chi YQ, 2014, P IEEE SEMICOND THER, P164, DOI 10.1109/SEMI-THERM.2014.6892234
[17]   Improving energy efficiency of dedicated cooling system and its contribution towards meeting an energy-optimized data center [J].
Cho, Jinkyun ;
Kim, Yundeok .
APPLIED ENERGY, 2016, 165 :967-982
[18]   Evaluation of air distribution system's airflow performance for cooling energy savings in high-density data centers [J].
Cho, Jinkyun ;
Yang, Joonyoung ;
Park, Woopyoung .
ENERGY AND BUILDINGS, 2014, 68 :270-279
[19]   Viability of datacenter cooling systems for energy efficiency in temperate or subtropical regions: Case study [J].
Cho, Jinkyun ;
Lim, Taesub ;
Kim, Byungseon Sean .
ENERGY AND BUILDINGS, 2012, 55 :189-197
[20]   Evaluation of air management system's thermal performance for superior cooling efficiency in high-density data centers [J].
Cho, Jinkyun ;
Kim, Byungseon Sean .
ENERGY AND BUILDINGS, 2011, 43 (09) :2145-2155