Review on Cooling System Energy Consumption in Internet Data Centers

被引:8
作者
Amoabeng, Kofi Owura [1 ]
Choi, Jong Min [2 ]
机构
[1] Hanbat Natl Univ, Grad Sch Mech Engn, 125 Dongseodaero Yuseong Gu, Daejeon 305719, South Korea
[2] Hanbat Natl Univ, Dept Mech Engn, 125 Dongseodaero Yuseong Gu, Daejeon 305719, South Korea
关键词
Energy consumption; data center; cooling system; power usage effectiveness;
D O I
10.1142/S2010132516300081
中图分类号
O414.1 [热力学];
学科分类号
摘要
Due to the advancement of the telecommunication and information technology (IT) industry, internet data centers (IDCs) have become widespread in the public and private sectors. As such, energy demand in the center has also become increasingly prominent. Several technologies on energy management have been studied to determine the options available to minimize the energy required to operate the data center as well as reduce greenhouse gas emissions. The cooling system is required to remove the high heat dissipated by the IT electronic components especially the servers in order to ensure safe and reliable working condition. However, it utilizes more than one-third of the total energy consumption in the data center. In this study, the energy effciency technologies that are usually applied to cooling systems in data centers were reviewed. The aim is to find out the strategies that will reduce the energy consumption of the cooling system since the cooling demand in data center is all year round. Prior to that, the performance metric tool that is mostly used in analyzing data center effciency was discussed. The conventional cooling system technologies that are utilized in data centers were also provided. Lastly, innovative cooling technologies for future solutions in data centers were discussed.
引用
收藏
页数:17
相关论文
共 88 条
[1]  
3M, 2015, 2 PHAS IMM COOL REV
[2]  
Alexander M., 2016, DATA CTR CCP REDUCIN
[3]   Computational fluid dynamic investigation of liquid rack cooling in data centres [J].
Almoli, Ali ;
Thompson, Adam ;
Kapur, Nikil ;
Summers, Jonathan ;
Thompson, Harvey ;
Hannah, George .
APPLIED ENERGY, 2012, 89 (01) :150-155
[4]  
[Anonymous], 2009, 99 ASHRAE TC
[5]  
[Anonymous], 2011, THERM GUID DAT PROC
[6]   The applied effect analysis of heat exchanger installed in a typical communication base station in Beijing of China [J].
Bao, Lingling ;
Wang, Jinggang ;
Kang, Ligai .
2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 :620-625
[7]  
Bedekar V, 2006, 2006 PROCEEDINGS 10TH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONICS SYSTEMS, VOLS 1 AND 2, P421
[8]  
Belady C., 2008, 6 GREEN GRID
[9]  
Bhopte S, 2006, 2006 PROCEEDINGS 10TH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONICS SYSTEMS, VOLS 1 AND 2, P426
[10]  
Boucher T.D., 2006, VIABILITY DYNAMIC CO