Reactive bandpass and low-pass filters often exhibit spurious responses in the frequency region above the design pass-band. The spurious responses limit the effectiveness of the filter in preventing interference by out-of-band signals. A simple and inexpensive technique for reducing or eliminating these passbands is to add short sections of an appropriate lossy transmission line in series with the conventionally filter. A significant size reduction of conventional transmission line reactive filters can also be realized along with the reduction or elimination of spurious passbands by combining a lossy dielectric with the conventional reactive elements. This paper discusses the application of lossy line filters in cascade with and integrated into conventional reactive filters. The design of lossy transmission line sections and wide-band impedance matching techniques are described. Copyright © 1968 by The Institute of Electrical and Electronics Engineers, Inc.