Preliminary Evaluation of a Novel Thermoplastic Mask System with Intra-fraction Motion Monitoring for Future Use with Image-Guided Gamma Knife

被引:21
作者
Li, Winnie [1 ]
Bootsma, Gregory [2 ]
Von Schultz, Oscar [3 ]
Carlsson, Per [3 ]
Laperriere, Normand [1 ]
Millar, Barbara-Ann [1 ]
Jaffray, David [1 ]
Chung, Caroline [4 ]
机构
[1] Univ Toronto, Princess Margaret Canc Ctr, Dept Radiat Oncol, Toronto, ON, Canada
[2] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
[3] Elekta Instruments AB, Elekta Res & Dev, Stockholm, Sweden
[4] Univ Toronto, Univ Hlth Network, Princess Margaret Hosp, Radiat Oncol,Radiat Med Program, Toronto, ON, Canada
来源
CUREUS | 2016年 / 8卷 / 03期
关键词
immobilization; intra-fraction motion; cone beam; stereotatic radiosurgery; optical tracking;
D O I
10.7759/cureus.531
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives A non-invasive immobilization system consisting of a thermoplastic mask with image-guidance using cone-beam CT (CBCT) and infrared (IR) tracking has been developed to ensure minimal inter- and intra-fractional movement during Gamma Knife radiosurgery. Prior to clinical use for patients on a Gamma Knife, this study clinically evaluates the accuracy and stability of this novel immobilization system with image-guidance in patients treated with standard fractionated radiation therapy on a linear accelerator. Materials & methods This prospective cohort study evaluated adult patients planned for fractionated brain radiotherapy. Patients were immobilized with a thermoplastic mask (with the nose cut out) and customized head cushion. A reflective marker was placed on the patient's nose tip and tracked with a stereoscopic IR camera throughout treatment. For each fraction, a pre-treatment, verification (after any translational correction for inter-fraction set-up variation), and post-treatment CBCT was acquired to evaluate inter- and intra-fraction movement of the target and nose. Intra-fraction motion of the nose tip measured on CBCT and IR tracking were compared. Results Corresponding data from 123 CBCT and IR datasets from six patients are summarized. The mean +/- standard deviation (SD) intra-fraction motion of the nose tip was 0.41 +/- 0.36 mm based on pre- and post-treatment CBCT data compared with 0.56 +/- 0.51 mm using IR tracking. The maximum intra-fraction motion of the nose tip was 1.7 mm using CBCT and 3.2 mm using IR tracking. The mean +/- SD intra-fraction motion of the target was 0.34 +/- 0.25 mm, and the maximum intra-fraction motion was 1.5 mm. Conclusions: This initial clinical evaluation of the thermoplastic mask immobilization system using both IR tracking and CBCT demonstrate that mean intra-fraction motion of the nose and target is small. The presence of isolated measures of larger intra-fraction motion supports the need for image-guidance and intra-fraction motion management when using this mask-based immobilization system for radiosurgery.
引用
收藏
页数:12
相关论文
共 19 条
  • [1] RELOCATABLE FRAME FOR STEREOTAXIC EXTERNAL BEAM RADIOTHERAPY
    GILL, SS
    THOMAS, DGT
    WARRINGTON, AP
    BRADA, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (03): : 599 - 603
  • [2] A NONINVASIVE, RELOCATABLE STEREOTAXIC FRAME FOR FRACTIONATED RADIOTHERAPY AND MULTIPLE IMAGING
    GRAHAM, JD
    WARRINGTON, AP
    GILL, SS
    BRADA, M
    [J]. RADIOTHERAPY AND ONCOLOGY, 1991, 21 (01) : 60 - 62
  • [3] Repositioning accuracy of a noninvasive head fixation system for stereotactic radiotherapy
    Hamilton, RJ
    Kuchnir, FT
    Pelizzari, CA
    Sweeney, PJ
    Rubin, SJ
    [J]. MEDICAL PHYSICS, 1996, 23 (11) : 1909 - 1917
  • [4] Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy
    Islam, Mohammad K.
    Purdie, Thomas G.
    Norrlinger, Bernhard D.
    Alasti, Hamideh
    Moseley, Douglas J.
    Sharpe, Michael B.
    Siewerdsen, Jeffrey H.
    Jaffray, David A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1573 - 1582
  • [5] ADAPTATION AND VERIFICATION OF THE RELOCATABLE GILL-THOMAS-COSMAN FRAME IN STEREOTAXIC RADIOTHERAPY
    KOOY, HM
    DUNBAR, SF
    TARBELL, NJ
    MANNARINO, E
    FERARRO, N
    SHUSTERMAN, S
    BELLERIVE, M
    FINN, L
    MCDONOUGH, CV
    LOEFFLER, JS
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (03): : 685 - 691
  • [6] STEREOTACTIC RADIOSURGERY
    LEKSELL, L
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1983, 46 (09) : 797 - 803
  • [7] LEKSELL L, 1951, ACTA CHIR SCAND, V102, P316
  • [8] Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging
    Li, Guang
    Ballangrud, Ase
    Kuo, Li Cheng
    Kang, Hyejoo
    Kirov, Assen
    Lovelock, Michael
    Yamada, Yoshiya
    Mechalakos, James
    Amols, Howard
    [J]. MEDICAL PHYSICS, 2011, 38 (07) : 3981 - 3994
  • [9] Deriving Planning Target Volume Margins for Intracranial Stereotactic Radiation Therapy
    Li, W.
    Craig, T.
    Cho, Y.
    Wang, A.
    Jaffray, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S732 - S732
  • [10] Geometric Performance and Efficiency of an Optical Tracking System for Daily Pre-treatment Positioning in Pelvic Radiotherapy Patients
    Li, Winnie
    Sie, Fanny
    Bootsma, Gregory
    Moseley, Douglas
    Catton, Charles N.
    Jaffray, David A.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2011, 10 (02) : 163 - 170