Comparison of the Measured Electrical Properties of Pig Internal Organs with the Given Values for Human Organs

被引:1
作者
Jung, Ji-Hyun [1 ]
Kim, Se-Yun [1 ]
机构
[1] Korea Inst Sci & Technol, Seoul, South Korea
关键词
Electrical Property; Open-Ended Coaxial Probe; Pig Internal Organ;
D O I
10.5515/JKIEES.2012.12.2.161
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The electrical properties of pig internal organs including lung, liver, heart, kidney, blood, stomach, and small intestine are measured using an open-ended coaxial probe and an improved virtual transmission-line model. The measured complex permittivities of the pig organs are compared with the given values of the corresponding human organs. A similarity between these values is confirmed. For organs such as lung, liver, heart, and kidney that have regular texture and contents, the complex permittivities are almost identical to those of the corresponding human organs. The complex permittivities of human and pig blood are also very close in value. However, relatively large deviations are observed for the cases of stomach and small intestine because the internal contents of these organs significantly affect the measured electrical properties.
引用
收藏
页码:161 / 165
页数:5
相关论文
共 8 条
[1]  
Chan YW, 2005, P ANN INT IEEE EMBS, P7754
[2]   Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz [J].
Chirwa, LC ;
Hammond, PA ;
Roy, S ;
Cumming, DRS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) :484-492
[3]   The dielectric properties of biological tissues .1. Literature survey [J].
Gabriel, C ;
Gabriel, S ;
Corthout, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2231-2249
[4]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[5]  
Jung J.-H., 2011, JKIEES, V11, P51
[6]   Electromagnetic Propagation From the Intestine-Ingested Source in the Human Body Model [J].
Jung, Ji-Hyun ;
Kim, Sang-Wook ;
Kim, Young-Sik ;
Kim, Se-Yun .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2010, 58 (05) :1683-1688
[7]   Radiowave propagation from a tissue-implanted source at 418 MHz and 916.5 MHz [J].
Scanlon, WG ;
Burns, JB ;
Evans, NE .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (04) :527-534
[8]   An efficient model of an open-ended coaxial-line probe for measuring the complex permittivity [J].
Shin, H ;
Hyun, SY ;
Kim, SW ;
Kim, SY .
SUBSURFACE SENSING TECHNOLOGIES AND APPLICATIONS II, 2000, 4129 :332-339