POSTERIOR PLATES IN THE MANAGEMENT OF CERVICAL INSTABILITY - LONG-TERM RESULTS IN 44 PATIENTS

被引:125
作者
FEHLINGS, MG
COOPER, PR
ERRICO, TJ
机构
[1] NYU,CTR MED,DEPT NEUROSURG,NEW YORK,NY 10016
[2] NYU,CTR MED,DEPT ORTHOPED SURG,NEW YORK,NY
关键词
PLATE FIXATION; CERVICAL SPINE; SPINE INSTABILITY; INSTRUMENTATION; BONE GRAFT;
D O I
10.3171/jns.1994.81.3.0341
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Although posterior plates are increasingly used to manage cervical spinal instability, long-term follow-up evaluation of patients with a critical analysis of efficacy and complications has not been reported. The authors have retrospectively analyzed the outcome in 44 consecutive patients (37 males and seven females, age range 16 to 80 years) treated with posterior cervical plates. The indications for instrumentation were instability due to trauma in 42 cases, tumor in one, and infection in one. In four patients the follow-up period was limited to 3, 5, 11, and 16 months. Two patients died of chronic medical problems 4 and 9 months after treatment. The remaining 38 patients were followed from 2 to 6 years (mean 46 months). One motion segment was stabilized in 23 patients using two-hole plates; two motion segments were stabilized in the other 21 patients using three-hole plates. In the majority of patients (37 cases), supplemental bone grafting was not used. Patients were immobilized postoperatively in a Philadelphia collar. Solid arthrodesis was achieved in 39 (93%) of 42 patients. Three patients required revision of the cervical plating: in one patient with a C-5 burst fracture, two-hole plates were applied at C5-6 and progressive kyphosis mandated anterior fusion; the second patient required posterior wiring due to screw pull-out resulting from a technical error in screw insertion; the third patient, who refused to wear an orthosis postoperatively, also developed screw pull-out, In two patients who went on to spinal fusion, there was an increase in sagittal kyphosis (6 degrees and 8 degrees) without clinical sequelae. Screw loosening was noted in five patients, involving eight (3.8%) of the 210 lateral mass screws; this complication resulted in instrumentation failure or increased kyphosis in three cases. There were two superficial infections. This analysis indicates that posterior cervical plating is highly effective; at long-term follow-up review the cervical spine was successfully stabilized in 93% of cases. Plate failure was related to faulty screw placement, failure to include sufficient motion segments, and noncompliance with postoperative orthoses. Halo vest immobilization was unnecessary and supplemental bone grafting was generally not required for recent trauma.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 16 条
  • [1] POSTERIOR CERVICAL ARTHRODESIS WITH AO RECONSTRUCTION PLATES AND BONE-GRAFT
    ANDERSON, PA
    HENLEY, MB
    GRADY, MS
    MONTESANO, PX
    WINN, HR
    [J]. SPINE, 1991, 16 (03) : S72 - S79
  • [2] FAILURE OF HALO VEST TO PREVENT INVIVO MOTION IN PATIENTS WITH INJURED CERVICAL SPINES
    ANDERSON, PA
    BUDORICK, TE
    EASTON, KB
    HENLEY, MB
    SALCICCIOLI, GG
    [J]. SPINE, 1991, 16 (10) : S501 - S505
  • [3] POSTERIOR STABILIZATION OF CERVICAL-SPINE FRACTURES AND SUBLUXATIONS USING PLATES AND SCREWS
    COOPER, PR
    COHEN, A
    ROSIELLO, A
    KOSLOW, M
    [J]. NEUROSURGERY, 1988, 23 (03) : 300 - 306
  • [4] BIOMECHANICS OF CERVICAL-SPINE FACETECTOMY AND FIXATION TECHNIQUES
    CUSICK, JF
    YOGANANDAN, N
    PINTAR, F
    MYKLEBUST, J
    HUSSAIN, H
    [J]. SPINE, 1988, 13 (07) : 808 - 812
  • [5] Domenella G, 1982, Ital J Orthop Traumatol, V8, P235
  • [6] Ebraheim N A, 1989, J Orthop Trauma, V3, P23, DOI 10.1097/00005131-198903010-00005
  • [7] PULLOUT STRENGTH COMPARISON OF 2 METHODS OF ORIENTING SCREW INSERTION IN THE LATERAL MASSES OF THE BOVINE CERVICAL-SPINE
    ERRICO, T
    UHL, R
    COOPER, P
    CASAR, R
    MCHENRY, T
    [J]. JOURNAL OF SPINAL DISORDERS, 1992, 5 (04): : 459 - 463
  • [8] POSTERIOR PLATING OF THE CERVICAL-SPINE - A BIOMECHANICAL COMPARISON OF DIFFERENT POSTERIOR FUSION TECHNIQUES
    GILL, K
    PASCHAL, S
    CORIN, J
    ASHMAN, R
    BUCHOLZ, RW
    [J]. SPINE, 1988, 13 (07) : 813 - 816
  • [9] ANATOMIC COMPARISON OF THE ROY-CAMILLE AND MAGERL TECHNIQUES FOR SCREW PLACEMENT IN THE LOWER CERVICAL-SPINE
    HELLER, JG
    CARLSON, GD
    ABITBOL, JJ
    GARFIN, SR
    [J]. SPINE, 1991, 16 (10) : S552 - S557
  • [10] POSTERIOR STABILIZATION OF THE CERVICAL-SPINE WITH HOOK PLATES
    JEANNERET, B
    MAGERL, F
    WARD, EH
    WARD, JC
    [J]. SPINE, 1991, 16 (03) : S56 - S63