Fixation Strength of Caudal Pedicle Screws after Posterior Lumbar Interbody Fusion with the Modified Cortical Bone Trajectory Screw Method

被引:13
作者
Sakaura, Hironobu [1 ]
Miwa, Toshitada [1 ]
Yamashita, Tomoya [2 ]
Kuroda, Yusuke [1 ]
Ohwada, Tetsuo [1 ]
机构
[1] Kansai Rosai Hosp, Dept Orthopaed Surg, 3-1-69 Inabaso, Amagasaki, Hyogo 6608511, Japan
[2] Osaka Rosai Hosp, Dept Orthopaed Surg, Osaka, Japan
关键词
Posterior lumbar interbody fusion; Less-invasive approach; Cortical bone trajectory; Caudal screw loosening; Risk factors;
D O I
10.4184/asj.2016.10.4.639
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Clinical case series. Purpose: In the posterior lumbar interbody fusion (PLIF) procedure in our institute, the cephalad screw trajectory follows a mediolateral and caudocephalad directed path according to the original cortical bone trajectory (CBT) method. However, the starting point of the caudal screw is at the medial border of the pedicle on an articular surface of the superior articular process, and the trajectory takes a mediolateral path parallel to the cephalad endplate. The incidence of caudal screw loosening after PLIF with this modified CBT screw method was investigated, and significant risk factors for caudal screw loosening were evaluated. Overview of Literature: A biomechanical study of this modified caudal screw trajectory using the finite element method reported about a 20% increase in uniaxial yield pullout load compared with the traditional trajectory. However, there has been no clinical study concerning the fixation strength of this modified caudal screw trajectory. Methods: The subjects were 193 consecutive patients who underwent single-level PLIF with modified CBT screw fixation. Caudal screw loosening was checked in computed tomography at 6 months after surgery, and screw loosening was defined as a radiolucency of 1 mm or more at the bone-screw interface. Results: The incidence of caudal screw loosening after lumbosacral PLIF (46.2%) was significantly higher than that after floating PLIF (6.0%). No significant differences in sex, brand of the instruments, and diameter and length of the caudal screw were evident between patients with and without caudal screw loosening. Patients with caudal screw loosening were significantly older at the time of surgery than patients without caudal screw loosening. Conclusions: Fixation strength of the caudal screw after floating PLIF with this modified CBT screw technique was sufficiently acceptable. Fixation strength after the lumbosacral procedure was not.
引用
收藏
页码:639 / 645
页数:7
相关论文
共 23 条
[1]   FUSION TO THE SACRUM FOR NONPARALYTIC SCOLIOSIS IN THE ADULT [J].
BALDERSTON, RA ;
WINTER, RB ;
MOE, JH ;
BRADFORD, DS ;
LONSTEIN, JE .
SPINE, 1986, 11 (08) :824-829
[2]   Effect of Physiological Loads on Cortical and Traditional Pedicle Screw Fixation [J].
Baluch, Daniel A. ;
Patel, Alpesh A. ;
Lullo, Brett ;
Havey, Robert M. ;
Voronov, Leonard I. ;
Ngoc-Lam Nguyen ;
Carandang, Gerard ;
Ghanayem, Alexander J. ;
Patwardhan, Avinash G. .
SPINE, 2014, 39 (22) :E1297-E1302
[3]   SCREW FIXATION IN THE HUMAN SACRUM - AN INVITRO STUDY OF THE BIOMECHANICS OF FIXATION [J].
CARLSON, GD ;
ABITBOL, JJ ;
ANDERSON, DR ;
KRAG, MH ;
KOSTUIK, JP ;
WOO, SLY ;
GARFIN, SR .
SPINE, 1992, 17 (06) :S196-S203
[4]   Internal architecture of the sacrum in the elderly - An anatomic and radiographic study [J].
Ebraheim, N ;
Sabry, FF ;
Nadim, Y ;
Xu, RM ;
Yeasting, RA .
SPINE, 2000, 25 (03) :292-297
[5]   Lumbar Transpedicular Implant Failure: A Clinical and Surgical Challenge and Its Radiological Assessment [J].
Eldin, Mohamed M. Mohi ;
Ali, Abdel Mohsen Arafa .
ASIAN SPINE JOURNAL, 2014, 8 (03) :281-297
[6]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239
[7]   Comparison of the strengths of lumbosacral fixation achieved with techniques using one and two triangulated sacral screws [J].
Leong, JCY ;
Lu, WW ;
Zheng, YG ;
Zhu, QG ;
Zhong, SZ .
SPINE, 1998, 23 (21) :2289-2294
[8]   Biomechanical evaluation of the fixation strength of lumbar pedicle screws using cortical bone trajectory: a finite element study [J].
Matsukawa, Keitaro ;
Yato, Yoshiyuki ;
Imabayashi, Hideaki ;
Hosogane, Naobumi ;
Asazuma, Takashi ;
Nemoto, Koichi .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 23 (04) :471-478
[9]   Cortical bone trajectory for lumbosacral fixation: penetrating S-1 endplate screw technique [J].
Matsukawa, Keitaro ;
Yato, Yoshiyuki ;
Kato, Takashi ;
Imabayashi, Hideaki ;
Asazuma, Takashi ;
Nemoto, Koichi .
JOURNAL OF NEUROSURGERY-SPINE, 2014, 21 (02) :203-209
[10]   Posterior lumbar interbody fusion - A retrospective study of complications after facet joint excision and pedicle screw fixation in 148 cases [J].
Okuyama, K ;
Abe, E ;
Suzuki, T ;
Tamura, Y ;
Chiba, M ;
Sato, K .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (04) :329-334