EVALUATION OF LOPHINE DERIVATIVES AS CHEMILUMINOGENS BY A FLOW-INJECTION METHOD

被引:94
作者
NAKASHIMA, K
YAMASAKI, H
KURODA, N
AKIYAMA, S
机构
[1] School of Pharmaceutical Sciences, Nagasaki University, Nagasaki, 852
关键词
CHEMILUMINESCENCE; FLOW INJECTION; LOPHINE;
D O I
10.1016/0003-2670(94)00360-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and convenient method for the evaluation of lophine (2,4,5-triphenylimidazole) derivatives as to their chemiluminescence efficiency was developed by using a flow-injection technique. Standard solutions of lophine derivatives were injected into a flow line containing a carrier solution (1.5 X 10(-4) M cobalt(II) containing 0.2% hydroxylammonium chloride in 75% methanol), which was successively combined with a flow line containing 100 mM hydrogen peroxide in H2O and a flow line containing 1.0 M KOH in H2O, and the chemiluminescence generated was monitored. Addition of hydroxylammonium chloride into a carrier solution resulted in a significant increase in chemiluminescence. Calibration graphs for eighteen derivatives were prepared and the relative chemiluminescence intensities were estimated from the slopes of these graphs. Among the derivatives, the compounds substituted by OCH, at the 2- and S-positions, and COOH, COCl, CONHNH2 and CONHNHCO(CH2)(4)CH3 at the 4-position on the phenyl ring at the 2-position of the imidazole skeleton showed large chemiluminescence intensities which are comparable to that of lophine. The detection limit of lophine was 72 fmol per injection at a signal-to-noise ratio of 2.
引用
收藏
页码:103 / 107
页数:5
相关论文
共 50 条
  • [21] EVALUATION OF A PREDICTIVE STEADY-STATE FLOW-INJECTION METHOD ADAPTED TO AN OPEN FLOW TUBE WITH A TRACER
    ROUSSIN, JA
    LI, JW
    PARDUE, HL
    ANALYTICA CHIMICA ACTA, 1995, 303 (2-3) : 199 - 210
  • [22] Flow-injection chemiluminescence determination of fluoroquinolones
    Rao, Y
    Tong, Y
    Zhang, XR
    Luo, GA
    Baeyens, WRG
    ANALYTICAL LETTERS, 2000, 33 (06) : 1117 - 1129
  • [23] KINETIC FLOW-INJECTION SPECTROFLUOROMETRIC METHOD FOR THE DETERMINATION OF FLUORIDE
    MARCO, V
    CARRILLO, F
    PEREZCONDE, C
    CAMARA, C
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 489 - 493
  • [24] Chemiluminescence determination of ultramicro DNA with a flow-injection method
    Chen, H
    Zhou, M
    Jin, XY
    Song, YM
    Zhang, ZY
    Ma, YJ
    ANALYTICA CHIMICA ACTA, 2003, 478 (01) : 31 - 36
  • [25] FLOW-INJECTION IMMUNOASSAYS
    GUBITZ, G
    SHELLUM, C
    ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 421 - 428
  • [26] Determination of norfloxacin by flow-injection chemiluminescence
    Liao, SL
    Xie, ZH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (12) : 1938 - 1942
  • [27] Determination of tsumacide residues in vegetable samples using a flow-injection chemiluminescence method
    Liu, Haiyan
    Hao, Yuhong
    Ren, Juanjuan
    He, Pingang
    Fang, Yuzhi
    LUMINESCENCE, 2007, 22 (04) : 302 - 308
  • [28] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [29] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [30] WAVELET TRANSFORM FOR THE EVALUATION OF PEAK INTENSITIES IN FLOW-INJECTION ANALYSIS
    BOS, M
    HOOGENDAM, E
    ANALYTICA CHIMICA ACTA, 1992, 267 (01) : 73 - 80