MICROWAVE SENSING OF PHYSIOLOGICAL MOVEMENT AND VOLUME CHANGE - A REVIEW

被引:206
作者
LIN, JC
机构
[1] Department of Electrical Engineering and Computer Science, University of Illinois at Chicago, Chicago
关键词
NONINVASIVE SENSING; REMOTE SENSING; HEART RATE; PULSE PRESSURE WAVE; EDEMA; RESPIRATION RATE;
D O I
10.1002/bem.2250130610
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The ability non-invasively to detect and monitor the movement of tissues and organs from outside the body provides many worthwhile areas of potential biomedical applications. Several non-invasive microwave techniques for contact and remote sensing of circulatory and respiratory movements and volume changes have been developed. In general, these systems consist of a microwave generator, a sampling device, a transmitting-receiving antenna, a set of signal-conditioning and processing devices, and a display unit. They operate at continuous-wave frequencies between 1 and 35 GHz and make use of amplitude and phase information derived from the received signal. The average power density of energy radiated by present systems ranges from approximately 0.001-1.0 mW/cm2. These systems are capable of registering instantaneous changes in fluid volume, pressure pulse, heart rate, and respiration rate in contact with body surface or at distances greater than 30 m, or behind thick layers of non-conductive walls.
引用
收藏
页码:557 / 565
页数:9
相关论文
共 22 条
[1]  
BYRNE W, 1986, IEEE T BIO-MED ENG, V33, P717, DOI 10.1109/TBME.1986.325763
[2]   MICROPROCESSOR-BASED CARDIOPULMONARY RATE MONITOR [J].
CHAN, KH ;
LIN, JC .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1987, 25 (01) :41-44
[3]   AN X-BAND MICROWAVE LIFE-DETECTION SYSTEM [J].
CHEN, KM ;
MISRA, D ;
WANG, H ;
CHUANG, HR ;
POSTOW, E .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (07) :697-701
[4]   AUTOMATIC CLUTTER-CANCELER FOR MICROWAVE LIFE-DETECTION SYSTEMS [J].
CHUANG, HR ;
CHEN, YF ;
CHEN, KM .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (04) :747-750
[5]   MICROWAVE SENSING OF INCREASED INTRACRANIAL WATER-CONTENT [J].
CLARKE, MJ ;
LIN, JC .
INVESTIGATIVE RADIOLOGY, 1983, 18 (03) :245-248
[6]   NONIONIZING ELECTROMAGNETIC WAVE EFFECTS IN BIOLOGICAL-MATERIALS AND SYSTEMS [J].
JOHNSON, CC ;
GUY, AW .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1972, 60 (06) :692-&
[7]   A MICROCPROCESSOR-BASED NONINVASIVE ARTERIAL PULSE-WAVE ANALYZER [J].
LEE, JY ;
LIN, JC .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (06) :451-455
[8]  
Lin J. C., 1986, MED APPL MICROWAVE I, P47
[9]   NONINVASIVE MICROWAVE MEASUREMENT OF RESPIRATION [J].
LIN, JC .
PROCEEDINGS OF THE IEEE, 1975, 63 (10) :1530-1530
[10]   MICROWAVE IMAGING OF CEREBRAL EDEMA [J].
LIN, JC ;
CLARKE, MJ .
PROCEEDINGS OF THE IEEE, 1982, 70 (05) :523-524