Electrical Impedance Tomography potential sensitivity

被引:0
|
作者
Sushko, I. [1 ]
Gaidayenko, Y. [1 ]
Yakubenko, O. [1 ]
机构
[1] Natl Tech Univ Ukraine, Kiev Polytech Inst, Kiev, Ukraine
来源
VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA | 2012年 / 50期
关键词
phantom; Electrical Impedance Tomography; sensitivity; increment; measuring accuracy; inhomogeneity;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The analysis of EIT phantom outline voltage measuring accuracy is carried out in this article. This accuracy is necessary for exposure of single inhomogeneity presence: "small" ( it's square is equal 3% of global phantom square), "middle" 08,5%) and "big" (19,59%) with different surface conductivity values of these inhomogeneities (background is phantom with surface conductivity s=1). Measuring was imitated by homogeneous phantom and phantoms with inhomogeneities voltage calculating and voltage difference computing (increment) between homogeneous phantom and phantoms with inhomogeneities. Inhomogeneities with bigger surface conductivity value than background conductivity value give significantly less voltage increments than inhomogeneities with smaller surface conductivity value than background. More sensitivity with closer position to phantom outline and bigger inhomogeneities size is illustrated by means of numerous increments values. Necessary measuring accuracy numerical assessments are proposed for considered inhomogeneities.
引用
收藏
页码:92 / 104
页数:13
相关论文
共 50 条
  • [41] Respiratory-gated electrical impedance tomography: a potential technique for quantifying stroke volume
    Arshad, Saaid H.
    Murphy, Ethan K.
    Halter, Ryan J.
    MEDICAL IMAGING 2016-BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2016, 9788
  • [42] Fisher information analysis in electrical impedance tomography
    Nordebo, Sven
    Gustafsson, Mats
    Nilsson, Borje
    Sjoden, Therese
    Soldovieri, Francesco
    JOURNAL OF GEOPHYSICS AND ENGINEERING, 2013, 10 (06)
  • [43] Roles of electrical impedance tomography in lung transplantation
    Jiang, Hui
    Han, Yijiao
    Zheng, Xia
    Fang, Qiang
    FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [44] Electrical impedance tomography: Standardizing the procedure in pneumology
    de Lema, Bruno
    Casan, Pere
    Riu, Pere
    ARCHIVOS DE BRONCONEUMOLOGIA, 2006, 42 (06): : 299 - 301
  • [45] A direct sampling method for electrical impedance tomography
    Chow, Yat Tin
    Ito, Kazufumi
    Zou, Jun
    INVERSE PROBLEMS, 2014, 30 (09)
  • [46] Detecting stochastic inclusions in electrical impedance tomography
    Barth, Andrea
    Harrach, Bastian
    Hyvoenen, Nuutti
    Mustonen, Lauri
    INVERSE PROBLEMS, 2017, 33 (11)
  • [47] DIRECT ELECTRICAL IMPEDANCE TOMOGRAPHY FOR NONSMOOTH CONDUCTIVITIES
    Astala, Kari
    Mueller, Jennifer L.
    Paivarinta, Lassi
    Peramaki, Allan
    Siltanen, Samuli
    INVERSE PROBLEMS AND IMAGING, 2011, 5 (03) : 531 - 549
  • [48] A direct reconstruction algorithm for electrical impedance tomography
    Mueller, JL
    Siltanen, S
    Isaacson, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (06) : 555 - 559
  • [49] Conditional Diffusion Model for Electrical Impedance Tomography
    Shi, Duanpeng
    Zheng, Wendong
    Guo, Di
    Liu, Huaping
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [50] Sparsity Constrained Reconstruction for Electrical Impedance Tomography
    Theertham, Ganesh Teja
    Varanasi, Santhosh Kumar
    Jampana, Phanindra
    IFAC PAPERSONLINE, 2020, 53 (02): : 362 - 367