Electrical Impedance Tomography potential sensitivity

被引:0
|
作者
Sushko, I. [1 ]
Gaidayenko, Y. [1 ]
Yakubenko, O. [1 ]
机构
[1] Natl Tech Univ Ukraine, Kiev Polytech Inst, Kiev, Ukraine
来源
VISNYK NTUU KPI SERIIA-RADIOTEKHNIKA RADIOAPARATOBUDUVANNIA | 2012年 / 50期
关键词
phantom; Electrical Impedance Tomography; sensitivity; increment; measuring accuracy; inhomogeneity;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The analysis of EIT phantom outline voltage measuring accuracy is carried out in this article. This accuracy is necessary for exposure of single inhomogeneity presence: "small" ( it's square is equal 3% of global phantom square), "middle" 08,5%) and "big" (19,59%) with different surface conductivity values of these inhomogeneities (background is phantom with surface conductivity s=1). Measuring was imitated by homogeneous phantom and phantoms with inhomogeneities voltage calculating and voltage difference computing (increment) between homogeneous phantom and phantoms with inhomogeneities. Inhomogeneities with bigger surface conductivity value than background conductivity value give significantly less voltage increments than inhomogeneities with smaller surface conductivity value than background. More sensitivity with closer position to phantom outline and bigger inhomogeneities size is illustrated by means of numerous increments values. Necessary measuring accuracy numerical assessments are proposed for considered inhomogeneities.
引用
收藏
页码:92 / 104
页数:13
相关论文
共 50 条
  • [21] Electrical impedance tomography in acute respiratory distress syndrome
    Bachmann, M. Consuelo
    Morais, Caio
    Bugedo, Guillermo
    Bruhn, Alejandro
    Morales, Arturo
    Borges, Joao B.
    Costa, Eduardo
    Retamal, Jaime
    CRITICAL CARE, 2018, 22
  • [22] Maximum entropy regularization method for electrical impedance tomography combined with a normalized sensitivity map
    Fan, W. R.
    Wang, H. X.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (03) : 277 - 283
  • [23] Sensitivity volume as figure-of-merit for maximizing data importance in electrical impedance tomography
    Onsager, Claire C.
    Wang, Chulin
    Costakis, Charles
    Aygen, Can C.
    Lang, Lauren
    van der Lee, Suzan
    Grayson, Matthew A.
    PHYSIOLOGICAL MEASUREMENT, 2024, 45 (04)
  • [24] Monitoring lungs with electrical impedance tomography
    Bevilacqua, Joyce Da Silva
    Yoshikawaz, Roberto Masaishi
    INVERSE PROBLEMS IN SCIENCE AND ENGINEERING, 2007, 15 (04) : 325 - 337
  • [25] Electrical impedance tomography with square sensor
    Zhang, Cao
    Wang, Huaxiang
    MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 792 - +
  • [26] SOURCE CONSISTENCY ELECTRICAL IMPEDANCE TOMOGRAPHY
    Zhang, Tingting
    Jang, Geuk Young
    Oh, Tong In
    Jeung, Kyung Woon
    Wi, Hun
    Woo, Eung Je
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2020, 80 (01) : 499 - 520
  • [27] Design of multiplexer for electrical impedance tomography
    Cagan, Jan
    Rosler, Jakub
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (05) : 5755 - 5760
  • [28] OPTIMAL TRANSPORTATION FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
    Bao, Gang
    Zhang, Yixuan
    MATHEMATICS OF COMPUTATION, 2024, 93 (349) : 2361 - 2389
  • [29] Electrical impedance tomography by elastic deformation
    Ammari, H.
    Bonnetier, E.
    Capdeboscq, Y.
    Tanter, M.
    Fink, M.
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2008, 68 (06) : 1557 - 1573
  • [30] A calculable sensor for electrical impedance tomography
    Cao, Zhang
    Wang, Huaxiang
    Yang, Wuqiang
    Yan, Yong
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 140 (02) : 156 - 161