The influence of Cr concentration on time resolution of GaAs detectors

被引:0
|
作者
Fedorenko, L. L. [1 ]
Linnik, L. F. [1 ]
Linnik, L. G. [1 ]
Yusupov, M. M. [1 ]
Solovyov, E. A. [1 ]
Sirmulis, E. [2 ]
机构
[1] NAS Ukraine, V Lashkaryov Inst Semicond Phys, 45 Prospect Nauky, UA-03028 Kiev, Ukraine
[2] Semicond Phys Inst, LT-01108 Vilnius, Lithuania
关键词
GaAs; fast detector; picosecond YAG-laser; X-; gamma-radiation; photo-conductivity;
D O I
暂无
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Investigated in this work were the influence of Cr dopant concentration and technological conditions of doping on photoconductivity (PhC) kinetics, dependence of PhC signal magnitude on voltage applied as well as the dynamic range of a photodetector based on semi-insulating GaAs:Cr. PhC relaxation was measured using a broadband system of registration in the picosecond pulse range, which is based on the oscillograph C7-19, CCD camera and personal computer. Mechanisms of recombination that influence on fast and slow components of the PhC signal were studied. The shortest time of PhC relaxation tau similar to 2.10(-10) s was observed in GaAs: Cr samples for the chromium dopant concentration N-Cr similar to 3.10(17) cm(-3). We have found a linear increase of the fast component of PhC with the intensity of excitation as well as a weak dependence at small levels and saturation at the high ones of excitation for the PhC slow component.
引用
收藏
页码:92 / 94
页数:3
相关论文
共 50 条
  • [1] HYDROGEN CONCENTRATION GAAS DETECTORS
    BEREZKIN, VA
    GRABCHAK, VP
    INKIN, VN
    RYCHKOV, GS
    SENSORS AND ACTUATORS A-PHYSICAL, 1991, 28 (03) : 191 - 195
  • [2] Influence of temperature on the energy resolution of sensors based on HR GaAs:Cr
    Lozinskaya, A.
    Veale, M. C.
    Kolesnikova, I
    Novikov, V
    Tolbanov, O.
    Tyazhev, A.
    Wheater, R. M.
    Zarubin, A.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (02)
  • [3] Measurement of the energy resolution and calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip
    Butler A.
    Butler P.
    Bell S.
    Chelkov G.A.
    Dedovich D.V.
    Demichev M.A.
    Elkin V.G.
    Gostkin M.I.
    Kotov S.A.
    Kozhevnikov D.A.
    Kruchonak U.G.
    Nozdrin A.A.
    Porokhovoy S.Y.
    Potrap I.N.
    Smolyanskiy P.I.
    Zakhvatkin M.M.
    Zhemchugov A.S.
    Physics of Particles and Nuclei Letters, 2015, 12 (1) : 59 - 73
  • [4] Properties of GaAs:Cr-based Timepix detectors
    Smolyanskiy, P.
    Bergmann, B.
    Chelkov, G.
    Kotov, S.
    Kruchonak, U.
    Kozhevnikov, D.
    Sierra, Y. Mora
    Stekl, I.
    Zhemchugov, A.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [5] Energy resolution in GaAs X- and γ-ray detectors
    Bertuccio, G
    Canali, C
    Nava, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 410 (01): : 29 - 35
  • [6] Influence of cooling on the working parameters of GaAs detectors
    Golovnia, SN
    Gorokhov, SA
    Tsyupa, YP
    Vorobiev, AP
    Koretskaja, OB
    Okaevich, LP
    Tolbanov, OP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 494 (1-3): : 223 - 228
  • [7] TIME RESOLUTION IN SEMICONDUCTOR-DETECTORS
    ELWAHAB, MA
    SAKKA, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 117 - 120
  • [8] NEUTRON DETECTORS WITH NANOSECOND TIME RESOLUTION
    KONONOV, VN
    POLETAEV, ED
    KAZAKOV, LE
    BOKHOVKO, MV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1979, 22 (03) : 696 - 700
  • [9] Gamma-ray detectors based on GaAs<Cr> for nanostructural investigations
    G. I. Ayzenshtat
    D. L. Budnitskii
    D. Yu. Mokeev
    V. A. Novikov
    E. M. Syresin
    O. P. Tolbanov
    A. V. Tyazhev
    G. A. Shelkov
    Russian Physics Journal, 2008, 51 : 1037 - 1052
  • [10] THEORETICAL ANALYSIS OF TIME RESOLUTION IN SCINTILLATION DETECTORS
    SIGFRIDSSON, B