NORMAL ABDOMINAL ENHANCEMENT PATTERNS WITH DYNAMIC GADOLINIUM-ENHANCED MR IMAGING

被引:48
作者
MIROWITZ, SA [1 ]
GUTIERREZ, E [1 ]
LEE, JKT [1 ]
BROWN, JJ [1 ]
HEIKEN, JP [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,EDWARD MALLINCKRODT INST RADIOL,ST LOUIS,MO 63110
关键词
ABDOMEN; MR STUDIES; GADOLINIUM; MAGNETIC RESONANCE (MR); TECHNOLOGY;
D O I
10.1148/radiology.180.3.1871272
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to quantitatively and qualitatively determine contrast enhancement patterns of normal abdominal organs with dynamic gadolinium-enhanced magnetic resonance (MR) imaging. Dynamic gadolinium-enhanced, T1-weighted, spin-echo imaging was performed during a 23-second breath hold in 38 patients, with images acquired before, during, and at 1, 2, and 5 minutes after bolus injection of gadopentetate dimeglumine. Enhancement patterns of normal liver, spleen, pancreas, adrenal gland, kidney, aorta, inferior vena cava, and fat were determined by visual evaluation and by performance of signal intensity measurements with an electronic cursor. Time-intensity curves demonstrated peak enhancement of all abdominal organs during or immediately after bolus injection of gadopentetate dimeglumine. MR enhancement patterns included visualization of renal cortical nephrogram and heterogeneous enhancement of the spleen during the bolus phase of contrast material administration. Peak enhancement of normal liver was 72%; spleen, 172%; pancreas, 82%; adrenal gland, 85%; and kidney, 291%. This study established reference data regarding abdominal organ enhancement that will be useful as dynamic gadolinium-enhanced MR imaging becomes clinically implemented.
引用
收藏
页码:637 / 640
页数:4
相关论文
共 12 条
[1]   FLOW PHENOMENA IN MR IMAGING [J].
BRADLEY, WG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (05) :983-994
[2]  
BRENNAN RE, 1979, INVEST RADIOL, V14, P239
[3]   CONTRAST ENHANCEMENT IN ABDOMINAL CT - BOLUS VS INFUSION [J].
BURGENER, FA ;
HAMLIN, DJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :351-358
[4]   CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING [J].
FOLEY, WD ;
BERLAND, LL ;
LAWSON, TL ;
SMITH, DF ;
THORSEN, MK .
RADIOLOGY, 1983, 147 (03) :797-803
[5]   DYNAMIC CT OF THE NORMAL SPLEEN [J].
GLAZER, GM ;
AXEL, L ;
GOLDBERG, HI ;
MOSS, AA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (02) :343-346
[6]   CONVENTIONAL AND RAPID MR IMAGING OF THE LIVER WITH GD-DTPA [J].
HAMM, B ;
WOLF, KJ ;
FELIX, R .
RADIOLOGY, 1987, 164 (02) :313-320
[7]   DYNAMIC GADOLINIUM-ENHANCED MR-IMAGING OF THE SPLEEN - NORMAL ENHANCEMENT PATTERNS AND EVALUATION OF SPLENIC LESIONS [J].
MIROWITZ, SA ;
BROWN, JJ ;
LEE, JKT ;
HEIKEN, JP .
RADIOLOGY, 1991, 179 (03) :681-686
[8]   DYNAMIC GADOLINIUM-ENHANCED RAPID ACQUISITION SPIN-ECHO MR IMAGING OF THE LIVER [J].
MIROWITZ, SA ;
LEE, JKT ;
GUTIERREZ, E ;
BROWN, JJ ;
HEIKEN, JP ;
EILENBERG, SS .
RADIOLOGY, 1991, 179 (02) :371-376
[9]   RAPID ACQUISITION SPIN-ECHO (RASE) MR IMAGING - A NEW TECHNIQUE FOR REDUCTION OF ARTIFACTS AND ACQUISITION TIME [J].
MIROWITZ, SA ;
LEE, JKT ;
BROWN, JJ ;
EILENBERG, SS ;
HEIKEN, JP ;
PERMAN, WH .
RADIOLOGY, 1990, 175 (01) :131-135
[10]   COMPARATIVE CHEMICAL-STRUCTURE AND PHARMACOKINETICS OF MRI CONTRAST AGENTS [J].
TWEEDLE, MF ;
EATON, SM ;
ECKELMAN, WC ;
GAUGHAN, GT ;
HAGAN, JJ ;
WEDEKING, PW ;
YOST, FJ .
INVESTIGATIVE RADIOLOGY, 1988, 23 :S236-S239