Cardiac Displacement During N-13-Ammonia Myocardial Perfusion PET/CT: Comparison Between Adenosine- and Regadenoson-Induced Stress

被引:15
作者
Vleeming, Elise J. [1 ,2 ]
Lazarenko, Sergiy V. [1 ,2 ]
van der Zant, Friso M. [1 ,2 ]
Pan, Xiao-Bo [3 ]
Declerck, Jerome M. [3 ]
Wondergem, Maurits [1 ,2 ]
Knol, Remco J. J. [1 ,2 ]
机构
[1] Northwest Clin, Cardiac Imaging Div Alkmaar, Alkmaar, Netherlands
[2] Northwest Clin, PET Ctr Northwest, Dept Nucl Med, Alkmaar, Netherlands
[3] Siemens Mol Imaging, Oxford, England
关键词
myocardial perfusion PET/CT; ammonia; motion artifacts; adenosine; regadenoson; pharmacologic stress;
D O I
10.2967/jnmt.117.199463
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study investigated differences in cardiac displacement during adenosine stress versus regadenoson stress in N-13-ammonia ((NH3)-N-13) MP PET/CT scans. Methods: In total, 61 myocardial perfusion PET/CT scans were acquired using either adenosine (n = 30) or regadenoson (n = 31) as a stressor. For both groups, cardiac displacement during rest and stress was measured 3-dimensionally, relative to either a fixed reference frame or the previous frame, in each 1-min frame of a list-mode PET acquisition of 25 min. All stress scans were additionally evaluated for the presence of motion artifacts. Also, the tolerability of the agents and the occurrence of side effects were compared between groups. Results: Significantly larger cardiac displacement during stress was detected in the adenosine group than in the regadenoson group, reflected by both maximal cardiac displacement (P = 0.022) and mean cardiac displacement (P = 0.001). The duration of the movement was typically shorter in the regadenoson group. Frames with cardiac displacement of at least 5 mm were observed nearly twice as frequently when adenosine was used instead of regadenoson. Conclusion: The displacement during regadenoson stress is of lower amplitude and shorter duration than that during adenosine stress and may therefore contribute to a lower incidence of motion artifacts on PET/CT scans.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 23 条
  • [1] Regadenoson: A New Myocardial Stress Agent
    Al Jaroudi, Wael
    Iskandrian, Ami E.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (13) : 1123 - 1130
  • [2] Value of exercise treadmill testing in women
    Alexander, KP
    Shaw, LJ
    DeLong, ER
    Mark, DB
    Peterson, ED
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (06) : 1657 - 1664
  • [3] Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT
    Bateman, TM
    Heller, GV
    McGhie, AI
    Friedman, JD
    Case, JA
    Bryngelson, JR
    Hertenstein, GK
    Moutray, KL
    Reid, K
    Cullom, SJ
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) : 24 - 33
  • [4] Cardiac Positron Emission Tomography
    Bengel, Frank M.
    Higuchi, Takahiro
    Javadi, Mehrbod S.
    Lautamaki, Riikka
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (01) : 1 - 15
  • [5] Burrell S, 2006, J NUCL MED TECHNOL, V34, P193
  • [6] Advances in pharmacologic agents in imaging: New A2A receptor agonists
    Cerqueira M.D.
    [J]. Current Cardiology Reports, 2006, 8 (2) : 119 - 122
  • [7] Cerqueira MD, 2004, AM J CARDIOL, V94, p33D
  • [8] SAFETY PROFILE OF ADENOSINE STRESS PERFUSION IMAGING - RESULTS FROM THE ADENOSCAN-MULTICENTER-TRIAL-REGISTRY
    CERQUEIRA, MD
    VERANI, MS
    SCHWAIGER, M
    HEO, J
    ISKANDRIAN, AS
    ALAZRAKI, NP
    BEAN, LC
    BELARDINELLI, L
    BELL, M
    BERMAN, DS
    BOTVINICK, EH
    CHEIRIF, J
    HANSEN, CL
    HELLER, GV
    JOHNSTON, DL
    LEPPO, JA
    MADDAHI, J
    PARKER, LS
    MOHIUDDIN, S
    RAICHLEN, JS
    REIS, GJ
    SCHELBERT, HR
    SEALS, AA
    STOLZENBERG, J
    WILLIAMS, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) : 384 - 389
  • [9] EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology
    Hesse, B
    Tägil, K
    Cuocolo, A
    Anagnostopoulos, C
    Bardiés, M
    Bax, J
    Bengel, F
    Sokole, EB
    Davies, G
    Dondi, M
    Edenbrandt, L
    Franken, P
    Kjaer, A
    Knuuti, J
    Lassmann, M
    Ljungberg, M
    Marcassa, C
    Marie, PY
    McKiddie, F
    O'Connor, M
    Prvulovich, E
    Underwood, R
    van Eck-Smit, B
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (07) : 855 - 897
  • [10] Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging
    Hunter, Chad R. R. N.
    Klein, Ran
    Beanlands, Rob S.
    deKemp, Robert A.
    [J]. MEDICAL PHYSICS, 2016, 43 (04) : 1829 - 1840