EVALUATION OF RESTRICTED ACCESS MEDIA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ANALYSIS OF SULFONAMIDE ANTIBIOTIC RESIDUES IN BOVINE SERUM

被引:25
作者
BREWSTER, JD
LIGHTFIELD, AR
BARFORD, RA
机构
[1] US Department of Agriculture, ARS, Eastern Regional Research Center, Philadelphia, PA 19118
来源
JOURNAL OF CHROMATOGRAPHY | 1992年 / 598卷 / 01期
关键词
D O I
10.1016/0021-9673(92)85110-F
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three commercially-available high-performance liquid chromatographic columns packed with restricted access media were evaluated for suitability in multi-residue direct injection analysis at the ng/ml level. The internal surface reversed-phase and shielded hydrophobic phase columns were not sufficiently retentive to separate all analytes from the tail of the matrix peak. Coelution of some of the analytes was also observed with these columns. The semi-permeable surface column was significantly more retentive and selective, providing good separation of analyte and matrix peaks. With this column, an analytical protocol requiring no organic solvents was developed for the assay of six sulfonamides at a detection limit of 25 ng/ml.
引用
收藏
页码:23 / 31
页数:9
相关论文
共 15 条
[1]   MONITORING OF VETERINARY DRUG RESIDUES BY A COMBINATION OF CONTINUOUS-FLOW TECHNIQUES AND COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. SULFONAMIDES IN EGG, MEAT AND MILK USING POST-COLUMN DERIVATIZATION WITH DIMETHYLAMINOBENZALDEHYDE [J].
AERTS, MML ;
BEEK, WMJ ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1988, 435 (01) :97-112
[2]   RAPID ELECTRODIALYTIC CLEANUP OF BIOLOGICAL SAMPLES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BREWSTER, JD ;
PIOTROWSKI, EG .
JOURNAL OF CHROMATOGRAPHY, 1991, 585 (02) :213-217
[3]   A NON-EXTRACTION HPLC METHOD FOR THE SIMULTANEOUS DETERMINATION OF SERUM PARACETAMOL AND SALICYLATE [J].
DAWSON, CM ;
WANG, TWM ;
RAINBOW, SJ ;
TICKNER, TR .
ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 :661-667
[4]   ELECTRODIALYTIC SAMPLE TREATMENT COUPLED ONLINE WITH HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DEBETS, AJJ ;
KOK, WT ;
HUPE, KP ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1990, 30 (7-8) :361-366
[5]   SEMIPERMEABLE-SURFACE REVERSED-PHASE MEDIA FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DESILETS, CP ;
ROUNDS, MA ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :25-39
[6]   HYDROPHILIC SHIELDING OF HYDROPHOBIC, CATION-EXCHANGE AND ANION-EXCHANGE PHASES FOR SEPARATION OF SMALL ANALYTES - DIRECT INJECTION OF BIOLOGICAL-FLUIDS ONTO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMNS [J].
FEIBUSH, B ;
SANTASANIA, CT .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :41-49
[7]  
FREI RW, 1988, J CHROMATOGRAPHY L A, V39
[8]  
FREI RW, 1989, J CHROMATOGRAPHY L B, V39
[9]   ZONE-ELECTROPHORETIC SAMPLE TREATMENT FOR LIQUID-CHROMATOGRAPHY [J].
KOK, WT ;
HUPE, KP ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1988, 436 (03) :421-427
[10]   THE INTERNAL SURFACE REVERSE PHASE - CONCEPTS AND APPLICATIONS [J].
PERRY, JA .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1990, 13 (06) :1047-1074