DETERMINATION OF CHLOROTRIAZINES IN AQUEOUS ENVIRONMENTAL-SAMPLES AT THE NG/1 LEVEL USING PRECONCENTRATION WITH A CATION EXCHANGER AND ONLINE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:49
作者
COQUART, V [1 ]
HENNION, MC [1 ]
机构
[1] ECOLE SUPER PHYS & CHIM IND,CHIM ANALYT LAB,10 RUE VAUQUELIN,F-75231 PARIS 05,FRANCE
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 585卷 / 01期
关键词
D O I
10.1016/0021-9673(91)85058-N
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
On-line precolumn sample handling was applied to preconcentrate chlorotriazines in aqueous samples prior to their high-performance liquid chromatographic separation. Chlorotriazines are ionizable compounds (pK(a) between 1.6 and 2) and a strong cation exchanger is used for their concentration. As the direct percolation of large aqueous sample volumes through a cation-exchange precolumn is impossible owing to the high concentrations of inorganic cations in natural waters, a two-step preconcentration has to be carried out. First. triazines are trapped in their neutral form by direct percolation of the aqueous sample through a first precolumn packed with the copolymer-based PRP-1 sorbent. In the second step, the PRP-1 precolumn is coupled to a second precolumn packed with a cation exchanger. A small volume of deionized water-acetonitrile mixture at pH 1 allows the triazines to be desorbed from the PRP-1 precolumn and concentrated on the cation exchange precolumn in their protonated form. The content of the cation exchange precolumn is analysed on-line using an acetonitrile water gradient. As the PRP-1 precolumn also acts as a powerful filter to many neutral interferents, detection limits are below the 10 ng/l level in drinking water.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 21 条
[1]   A REVIEW OF LIQUID-CHROMATOGRAPHY IN ENVIRONMENTAL PESTICIDE ANALYSIS [J].
BARCELO, D .
CHROMATOGRAPHIA, 1988, 25 (10) :928-936
[2]  
BARRISTA M, 1989, ANAL CHEM, V61, P935
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DETERMINING TRIAZINE HERBICIDE RESIDUES IN SOIL [J].
BATTISTA, M ;
DICORCIA, A ;
MARCHETTI, M .
JOURNAL OF CHROMATOGRAPHY, 1988, 454 :233-242
[4]   LIQUID-CHROMATOGRAPHIC SEPARATION AND BEHAVIOR OF SOME TRIAZINES ON STYRENE DIVINYLBENZENE COLUMNS [J].
COPPI, S ;
BETTI, A .
JOURNAL OF CHROMATOGRAPHY, 1989, 472 (02) :406-410
[5]   RAPID-DETERMINATION OF SIMAZINE AND ATRAZINE IN WATER AT THE PARTS-PER-TRILLION (1012) LEVEL - EXTRACTION BY A MINIATURIZED CARBOPACK-B TRAP FOLLOWED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
DICORCIA, A ;
MARCHETTI, M ;
SAMPERI, R .
JOURNAL OF CHROMATOGRAPHY, 1987, 405 :357-363
[6]   A RAPID AND SENSITIVE HPLC PROCEDURE FOR THE DETERMINATION OF ATRAZINE RESIDUES IN SOIL-WATER EXTRACTS [J].
FERRIS, IG ;
HAIGH, BM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (04) :170-179
[7]   OPTIMIZATION OF PRECOLUMN DESIGN IN LIQUID-CHROMATOGRAPHY [J].
GOEWIE, CE ;
NIELEN, MWF ;
FREI, RW ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (02) :325-334
[8]   COUPLED REVERSED-PHASE LIQUID-CHROMATOGRAPHY CAPILLARY GAS-CHROMATOGRAPHY FOR THE DETERMINATION OF ATRAZINE IN WATER [J].
GROB, K ;
LI, ZW .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02) :423-430
[9]  
GROHLICH D, 1989, J HIGH RES CHROMATOG, V12, P340
[10]   HIGH-PERFORMANCE-LIQUID CHROMATOGRAPHIC-SEPARATION OF 1,3,5-TRIAZINE HERBICIDES [J].
GUNTHER, WJ ;
KETTRUP, A .
CHROMATOGRAPHIA, 1989, 28 (3-4) :209-211