摘要
The purpose of this work was to examine in vivo the safety of sonication in the coronary arteries in a live animal model. In intact dogs (n = 8), balloon dilatation was performed on the proximal left anterior descending artery (LAD) followed by sonication to the left circumflex artery (LCX) in power levels found to be optimal for thrombus ablation. Post-dilatation and post-ultrasound coronary angiography, echocardiography, histopathology, CK-MB, indices of hemolysis, and coagulation were compared. Sonication did not induce changes in the ECG or blood pressure. Coronary angiography revealed no adverse side effects or change in arterial diameter (2.3 +/- 0.7 vs. 2.4 +/- 0.3 mm). Echocardiography showed transient opacification of the myocardium. Histopathology revealed a comparable minimal degree of endothelial denudation. After sonication there were no changes in the level of CK-MB (312 +/- 168 vs. 283 +/- 207 IU), hemoglobin (11.3 +/- 0.9 vs. 12.7 +/- 1.1 gr%), haptoglobin (479 +/- 136 vs. 451 +/- 121 mg/dL), fibrinogen (142 +/- 18 vs, 165 +/- 28 mg%), partial thromboplastin time (17.3 +/- 3.2 vs. 17.6 +/- 3.4 sec), prothrombin time (13.3 +/- 7.8 vs. 11.5 +/- 2.9 sec), and degree of platelet aggregation (55 +/- 17 vs. 62 +/- 8%), Thus, the data suggest that transluminal coronary sonication exerts no overt adverse effects invivo. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [11] Anatomical Study of Forearm Arteries With Ultrasound for Percutaneous Coronary Procedures
    Yan, Zhen-xian
    Zhou, Yu-jie
    Zhao, Ying-xin
    Zhou, Zhi-ming
    Yang, Shi-wei
    Wang, Zhi-jian
    CIRCULATION JOURNAL, 2010, 74 (04) : 686 - 692
  • [12] MORPHOLOGICAL EFFECTS OF CORONARY BALLOON ANGIOPLASTY INVIVO ASSESSED BY INTRAVASCULAR ULTRASOUND IMAGING
    HONYE, J
    MAHON, DJ
    JAIN, A
    WHITE, CJ
    RAMEE, SR
    WALLIS, JB
    ALZARKA, A
    TOBIS, JM
    CIRCULATION, 1992, 85 (03) : 1012 - 1025
  • [13] Effects of intracoronary β-radiation therapy after coronary angioplasty -: An intravascular ultrasound study
    Meerkin, D
    Tardif, JC
    Crocker, IR
    Arsenault, A
    Joyal, M
    Lucier, G
    King, SB
    Williams, DO
    Serruys, PW
    Bonan, R
    CIRCULATION, 1999, 99 (13) : 1660 - 1665
  • [14] Perivascular inflammation after balloon angioplasty of porcine coronary arteries
    Okamoto, E
    Couse, T
    De Leon, H
    Vinten-Johansen, J
    Goodman, RB
    Scott, NA
    Wilcox, JN
    CIRCULATION, 2001, 104 (18) : 2228 - 2235
  • [15] Prevention of restenosis after angioplasty in small coronary arteries with probucol
    Rodés, J
    Côté, G
    Lespérance, J
    Bourassa, MG
    Doucet, S
    Bilodeau, L
    Bertrand, OF
    Harel, F
    Gallo, R
    Tardif, JC
    CIRCULATION, 1998, 97 (05) : 429 - 436
  • [16] BALLOON ANGIOPLASTY OF TOTALLY AND SUBTOTALLY OCCLUDED CORONARY-ARTERIES - RESULTS USING THE HYDROPHILLIC TERUMO RADIFOCUS GUIDEWIRE-M (GLIDEWIRE)
    GRAY, DF
    SIVANANTHAN, UM
    VERMA, SP
    MICHALIS, LK
    REES, MR
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (04): : 293 - 299
  • [17] Effects of percutaneous transluminal coronary angioplasty on coronary adenosine concentrations in humans
    Paganelli, F
    Saadjian, A
    Sampol, JJ
    Maixent, JM
    Levy, S
    Guieu, R
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2000, 30 (02) : 105 - 110
  • [18] Medical progress exemplified by improvements in the safety coronary angioplasty
    Metzger, Jean-Philippe
    BULLETIN DE L ACADEMIE NATIONALE DE MEDECINE, 2012, 196 (07): : 1361 - 1367
  • [19] Safety of low dose heparin in elective coronary angioplasty
    Koch, KT
    Piek, JJ
    deWinter, RJ
    David, GK
    Mulder, K
    Tijssen, JGP
    Lie, KI
    HEART, 1997, 77 (06) : 517 - 522
  • [20] Stent placement to prevent restenosis after angioplasty in small coronary arteries
    Doucet, S
    Schalij, MJ
    Vrolix, MCM
    Hilton, D
    Chenu, P
    de Bruyne, B
    Udayachalerm, W
    Seth, A
    Bilodeau, L
    Reiber, JHC
    Harel, F
    Lespérance, J
    CIRCULATION, 2001, 104 (17) : 2029 - 2033