COMPARISON OF MAGNETIC-RESONANCE VOLUME FLOW-RATES, ANGIOGRAPHY, AND CAROTID DOPPLERS - PRELIMINARY-RESULTS

被引:37
作者
LEVINE, RL
TURSKI, PA
HOLMES, KA
GRIST, TM
机构
[1] UNIV WISCONSIN, CTR CLIN SCI, DEPT NEUROL, MADISON, WI USA
[2] UNIV WISCONSIN, CTR CLIN SCI, DEPT RADIOL, MADISON, WI USA
关键词
ANGIOGRAPHY; MAGNETIC RESONANCE; CAROTID ARTERIES; MAGNETIC RESONANCE IMAGING; ULTRASONICS;
D O I
10.1161/01.STR.25.2.413
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. Methods From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied with all three techniques. The studies were independently read, and regression analysis was used to compare the measurements. Results Carotid Doppler measurements of the distal extracranial carotid arteries were proportional to the inverse of the extracranial carotid volume flow rate (r=.53, R(2)=29%, P<.01), volume flow rates were proportional to the inverse of measured percent stenosis on angiography (r=.84, R(2)=71%, P<.01), and Dopplers were proportional to angiography (r=.94, R(2)=90%, P<.01). Symptomatic Doppler systolic velocity was significantly higher (P<.002), symptomatic measured stenosis was significantly higher (P<.002), and symptomatic volume flow rate was significantly lower (P<.01) than their respective asymptomatic-side values. These preliminary observations, however, may well change once a large data set, especially one in which more patients with high-grade carotid stenosis are included, is studied. Conclusions Assessment of carotid volume flow rates by magnetic resonance angiography quantifies flow reduction secondary to atherosclerotic occlusive disease. The easily obtained flow data add both documentation of arterial flow characteristics related to internal carotid stenosis and information regarding the adequacy of collateral pathways.
引用
收藏
页码:413 / 417
页数:5
相关论文
共 23 条
[1]   MR FLOW IMAGING BY VELOCITY-COMPENSATED UNCOMPENSATED DIFFERENCE IMAGES [J].
AXEL, L ;
MORTON, D .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :31-34
[2]   BLOOD-FLOW IN THE CAROTID ARTERIES - QUANTIFICATION BY USING PHASE-SENSITIVE MR IMAGING [J].
BENDEL, P ;
BUONOCORE, E ;
BOCKISCH, A ;
BESOZZI, MC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (06) :1307-1310
[3]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[4]  
CROSBY DL, 1992, NEUROIMAG CLIN N AM, V2, P509
[5]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[6]   3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY [J].
DUMOULIN, CL ;
SOUZA, SP ;
WALKER, MF ;
WAGLE, W .
MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) :139-149
[7]   QUANTIFICATION OF BLOOD-FLOW WITH DYNAMIC MR IMAGING AND PRESATURATION BOLUS TRACKING [J].
EDELMAN, RR ;
MATTLE, HP ;
KLEEFIELD, J ;
SILVER, MS .
RADIOLOGY, 1989, 171 (02) :551-556
[8]   MAGNETIC-RESONANCE-IMAGING OF BLOOD-FLOW WITH A PHASE SUBTRACTION TECHNIQUE - INVITRO AND INVIVO VALIDATION [J].
EVANS, AJ ;
IWAI, F ;
GRIST, TA ;
SOSTMAN, HD ;
HEDLUND, LW ;
SPRITZER, CE ;
NEGROVILAR, R ;
BEAM, CA ;
PELC, NJ .
INVESTIGATIVE RADIOLOGY, 1993, 28 (02) :109-115
[9]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532
[10]   RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION [J].
KONDO, C ;
CAPUTO, GR ;
SEMELKA, R ;
FOSTER, E ;
SHIMAKAWA, A ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :9-16