Eight different modifications of the same single tissue compartment model to measure myocardial blood flow, based on inhalation of O-15-labelled CO2 and positron emission tomography, were assessed in both dogs and human normal volunteers. Several models provided results with the same degree of accuracy in dogs. However, a number of these models gave poorer results in humans. It was established that the model containing components for blood flow, fraction of water exchanging tissue and spill-over arterial blood volume provided the most accurate and reproducible results. This model contains inherent corrections for the limited spatial resolution of positron emission tomographs. For ease of computation, linearisation of the operational (fitting) equation was tested, but found not to be satisfactory. The left atrium was slightly better than the left ventricle for determining the arterial input function. Inclusion of the blood volume term in the fitting procedure was significantly better than subtracting blood volume prior to analysis, both in terms of accuracy and precision.
引用
收藏
页码:1 / 20
页数:20
相关论文
共 40 条
  • [1] Altman P. L., 1971, RESPIRATION CIRCULAT
  • [2] NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW IN CORONARY-ARTERY DISEASE WITH OXYGEN-15-LABELED CARBON-DIOXIDE INHALATION AND POSITRON EMISSION TOMOGRAPHY
    ARAUJO, LI
    LAMMERTSMA, AA
    RHODES, CG
    MCFALLS, EO
    IIDA, H
    RECHAVIA, E
    GALASSI, A
    DESILVA, R
    JONES, T
    MASERI, A
    [J]. CIRCULATION, 1991, 83 (03) : 875 - 885
  • [3] BELLINA CR, 1990, J NUCL MED, V31, P1335
  • [4] NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY
    BERGMANN, SR
    HERRERO, P
    MARKHAM, J
    WEINHEIMER, CJ
    WALSH, MN
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) : 639 - 652
  • [5] QUANTIFICATION OF REGIONAL MYOCARDIAL BLOOD-FLOW INVIVO WITH (H2O)-O-15
    BERGMANN, SR
    FOX, KAA
    RAND, AL
    MCELVANY, KD
    WELCH, MJ
    MARKHAM, J
    SOBEL, BE
    [J]. CIRCULATION, 1984, 70 (04) : 724 - 733
  • [7] INFARCTION SIZING AND MYOCARDIAL PERFUSION MEASUREMENTS USING RUBIDIUM-82 AND POSITRON EMISSION TOMOGRAPHY
    BUDINGER, TF
    YANO, Y
    DERENZO, SE
    HUESMAN, RH
    YEN, CK
    MOYER, BR
    SHERMAN, LG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02) : 399 - 399
  • [8] SMALL VESSEL AND TOTAL CORONARY BLOOD-VOLUME DURING INTRA-CORONARY ADENOSINE
    CRYSTAL, GJ
    DOWNEY, HF
    BASHOUR, FA
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1981, 241 (02): : H194 - H201
  • [9] EVIDENCE OF LIMITATIONS OF WATER AS A FREELY DIFFUSIBLE TRACER IN BRAIN OF RHESUS-MONKEY
    EICHLING, JO
    RAICHLE, ME
    GRUBB, RL
    TERPOGOS.MM
    [J]. CIRCULATION RESEARCH, 1974, 35 (03) : 358 - 364
  • [10] EXTRACTION OF WATER LABELED WITH O-15 DURING SINGLE-CAPILLARY TRANSIT - INFLUENCE OF BLOOD-PRESSURE, OSMOLARITY, AND BLOOD-BRAIN-BARRIER DAMAGE
    GO, KG
    LAMMERTSMA, AA
    PAANS, AMJ
    VAALBURG, W
    WOLDRING, MG
    [J]. ARCHIVES OF NEUROLOGY, 1981, 38 (09) : 581 - 584