SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING

被引:56
|
作者
DUDA, SH [1 ]
LANIADO, M [1 ]
KOPP, AF [1 ]
GRONEWALLER, E [1 ]
AICHER, KP [1 ]
PAVONE, P [1 ]
JEHLE, E [1 ]
CLAUSSEN, CD [1 ]
机构
[1] UNIV ROMA LA SAPIENZA, DEPT RADIOL, I-00185 ROME, ITALY
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; EFFECTS; IRON; LIVER; LIVER NEOPLASMS; DIAGNOSIS;
D O I
10.1002/jmri.1880040314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AMI-25 was evaluated at 1.5 T as a superparamagnetic iron oxide contrast agent for the liver. Sixteen patients with up to five suspected focal liver lesions were examined with T1-, proton-density-, and T2-weighted spin-echo sequences before and after intravenous administration of AMI-25 (15 mumol/kg iron). The contrast-to-noise ratio (C/N) increased from 1.8 to 3.5 on 600/15 (TR msec/TE msec) images and from 1.7 to 7.9 on 2,500/15 images after AMI-25 administration (P < .01). C/N did not change significantly on 2.500/90 images. Two blinded readers counted the number of lesions visible on unenhanced and contrast-enhanced images, with the 32 sets of images of the 16 patients presented in random order. Both readers identified more lesions on AMI-25-enhanced images, but the difference was not statistically significant (P > .05). Two patients reported minor side effects (flushing, sensation of heat, lower back pain). On the basis of the results obtained in a limited number of patients, the authors conclude that at 1.5 T. AMI-25 does not significantly improve the detection of focal liver lesions on conventional spin-echo images.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 50 条
  • [21] HYPERVASCULAR MALIGNANT LIVER-LESIONS - COMPARISON OF VARIOUS MR-IMAGING PULSE SEQUENCES AND DYNAMIC CT
    LARSON, RE
    SEMELKA, RC
    BAGLEY, AS
    MOLINA, PL
    BROWN, ED
    LEE, JKT
    RADIOLOGY, 1994, 192 (02) : 393 - 399
  • [22] ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE - CHARACTERIZATION OF A NEW CLASS OF CONTRAST AGENTS FOR MR IMAGING
    WEISSLEDER, R
    ELIZONDO, G
    WITTENBERG, J
    RABITO, CA
    BENGELE, HH
    JOSEPHSON, L
    RADIOLOGY, 1990, 175 (02) : 489 - 493
  • [23] MR TOMOGRAPHY OF FOCAL LIVER-LESIONS USING THE SUPERPARAMAGNETIC CONTRAST AGENT AMI-25 AT 1.5 TESLA
    DUDA, SH
    LANIADO, M
    KOPP, AF
    GRONEWALLER, E
    AICHER, KP
    PAVONE, P
    JEHLE, E
    CLAUSSEN, CD
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (01): : 46 - 51
  • [24] ULTRASMALL SUPERPARAMAGNETIC IRON-OXIDE - AN INTRAVENOUS CONTRAST AGENT FOR ASSESSING LYMPH-NODES WITH MR IMAGING
    WEISSLEDER, R
    ELIZONDO, G
    WITTENBERG, J
    LEE, AS
    JOSEPHSON, L
    BRADY, TJ
    RADIOLOGY, 1990, 175 (02) : 494 - 498
  • [25] MR imaging of the liver and spleen: A comparison of the effects on signal intensity of two superparamagnetic iron oxide agents
    Chen, F
    Ward, J
    Robinson, PJ
    MAGNETIC RESONANCE IMAGING, 1999, 17 (04) : 549 - 556
  • [26] CARDIOVASCULAR MR IMAGING WITH IRON-OXIDE PARTICLES - UTILITY OF A SUPERPARAMAGNETIC CONTRAST AGENT AND THE ROLE OF DIFFUSION IN SIGNAL LOSS
    ROZENMAN, Y
    ZOU, XM
    KANTOR, HL
    RADIOLOGY, 1990, 175 (03) : 655 - 659
  • [27] HEPATOCELLULAR-CARCINOMA IN CIRRHOTIC LIVERS - DETECTION WITH UNENHANCED AND IRON OXIDE-ENHANCED MR-IMAGING
    YAMAMOTO, H
    YAMASHITA, Y
    YOSHIMATSU, S
    BABA, Y
    HATANAKA, Y
    MURAKAMI, R
    NISHIHARU, T
    TAKAHASHI, M
    HIGASHIDA, Y
    MORIBE, N
    RADIOLOGY, 1995, 195 (01) : 106 - 112
  • [28] HEPATIC MR-IMAGING WITH FERUMOXIDES - A MULTICENTER CLINICAL-TRIAL OF THE SAFETY AND EFFICACY IN THE DETECTION OF FOCAL HEPATIC-LESIONS
    ROS, PR
    FREENY, PC
    HARMS, SE
    SELTZER, SE
    DAVIS, PL
    CHAN, TW
    STILLMAN, AE
    MUROFF, LR
    RUNGE, VM
    NISSENBAUM, MA
    JACOBS, PM
    RADIOLOGY, 1995, 196 (02) : 481 - 488
  • [29] Diagnostic accuracy of MR imaging to identify and characterize focal liver lesions: comparison between gadolinium and superparamagnetic iron oxide contrast media
    Maurea, Simone
    Mainenti, Pier Paolo
    Tambasco, Annamaria
    Imbriaco, Massimo
    Mollica, Carmine
    Laccetti, Ettore
    Camera, Luigi
    Liuzzi, Raffaele
    Salvatore, Marco
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2014, 4 (03) : 181 - 189
  • [30] Efficacy of sequential use of superparamagnetic iron oxide and gadolinium in liver MR imaging
    Halavaara, J
    Tervahartiala, R
    Isoniemi, H
    Höckerstedt, K
    ACTA RADIOLOGICA, 2002, 43 (02) : 180 - 185