SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING

被引:56
作者
DUDA, SH [1 ]
LANIADO, M [1 ]
KOPP, AF [1 ]
GRONEWALLER, E [1 ]
AICHER, KP [1 ]
PAVONE, P [1 ]
JEHLE, E [1 ]
CLAUSSEN, CD [1 ]
机构
[1] UNIV ROMA LA SAPIENZA, DEPT RADIOL, I-00185 ROME, ITALY
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; EFFECTS; IRON; LIVER; LIVER NEOPLASMS; DIAGNOSIS;
D O I
10.1002/jmri.1880040314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AMI-25 was evaluated at 1.5 T as a superparamagnetic iron oxide contrast agent for the liver. Sixteen patients with up to five suspected focal liver lesions were examined with T1-, proton-density-, and T2-weighted spin-echo sequences before and after intravenous administration of AMI-25 (15 mumol/kg iron). The contrast-to-noise ratio (C/N) increased from 1.8 to 3.5 on 600/15 (TR msec/TE msec) images and from 1.7 to 7.9 on 2,500/15 images after AMI-25 administration (P < .01). C/N did not change significantly on 2.500/90 images. Two blinded readers counted the number of lesions visible on unenhanced and contrast-enhanced images, with the 32 sets of images of the 16 patients presented in random order. Both readers identified more lesions on AMI-25-enhanced images, but the difference was not statistically significant (P > .05). Two patients reported minor side effects (flushing, sensation of heat, lower back pain). On the basis of the results obtained in a limited number of patients, the authors conclude that at 1.5 T. AMI-25 does not significantly improve the detection of focal liver lesions on conventional spin-echo images.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 24 条
[11]  
HILLMAN RS, 1990, PHARMACOL BASIS THER, P1277
[12]   DETECTION OF LIVER METASTASES WITH SUPERPARAMAGNETIC IRON-OXIDE IN 15 PATIENTS - RESULTS OF MR IMAGING AT 1.5-T [J].
MARCHAL, G ;
VANHECKE, P ;
DEMAEREL, P ;
DECROP, E ;
KENNIS, C ;
BAERT, AL ;
VANDERSCHUEREN, E .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (04) :771-775
[13]   DYNAMIC GADOLINIUM-ENHANCED RAPID ACQUISITION SPIN-ECHO MR IMAGING OF THE LIVER [J].
MIROWITZ, SA ;
LEE, JKT ;
GUTIERREZ, E ;
BROWN, JJ ;
HEIKEN, JP ;
EILENBERG, SS .
RADIOLOGY, 1991, 179 (02) :371-376
[14]  
MUDGE GH, 1990, PHARMACOL BASIS THER, P682
[15]   INTRAARTERIAL PORTOGRAPHY WITH GADOPENTETATE DIMEGLUMINE - IMPROVED LIVER-TO-LESION CONTRAST IN MR-IMAGING [J].
PAVONE, P ;
GIULIANI, S ;
CARDONE, G ;
OCCHIATO, R ;
DIRENZI, P ;
PETRONI, GA ;
BUONI, C ;
PASSARIELLO, R .
RADIOLOGY, 1991, 179 (03) :693-697
[16]   DYNAMIC SIGNAL INTENSITY CHANGES IN LIVER WITH SUPERPARAMAGNETIC MR CONTRAST AGENTS [J].
REIMER, P ;
KWONG, KK ;
WEISSKOFF, R ;
COHEN, MS ;
BRADY, TJ ;
WEISSLEDER, R .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02) :177-181
[17]   FERRITE PARTICLES - A SUPERPARAMAGNETIC MR CONTRAST AGENT FOR ENHANCED DETECTION OF LIVER-CARCINOMA [J].
SAINI, S ;
STARK, DD ;
HAHN, PF ;
BOUSQUET, JC ;
INTROCASSO, J ;
WITTENBERG, J ;
BRADY, TJ ;
FERRUCCI, JT .
RADIOLOGY, 1987, 162 (01) :217-222
[18]   FERRITE PARTICLES - A SUPERPARAMAGNETIC MR CONTRAST AGENT FOR THE RETICULOENDOTHELIAL SYSTEM [J].
SAINI, S ;
STARK, DD ;
HAHN, PF ;
WITTENBERG, J ;
BRADY, TJ ;
FERRUCCI, JT .
RADIOLOGY, 1987, 162 (01) :211-216
[19]  
SEIFEN E, 1992, ALLGEMEINE SPEZIELLE, P404
[20]   SUPERPARAMAGNETIC IRON-OXIDE - CLINICAL-APPLICATION AS A CONTRAST AGENT FOR MR IMAGING OF THE LIVER [J].
STARK, DD ;
WEISSLEDER, R ;
ELIZONDO, G ;
HAHN, PF ;
SAINI, S ;
TODD, LE ;
WITTENBERG, J ;
FERRUCCI, JT .
RADIOLOGY, 1988, 168 (02) :297-301