SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING

被引:56
|
作者
DUDA, SH [1 ]
LANIADO, M [1 ]
KOPP, AF [1 ]
GRONEWALLER, E [1 ]
AICHER, KP [1 ]
PAVONE, P [1 ]
JEHLE, E [1 ]
CLAUSSEN, CD [1 ]
机构
[1] UNIV ROMA LA SAPIENZA, DEPT RADIOL, I-00185 ROME, ITALY
关键词
CONTRAST ENHANCEMENT; CONTRAST MEDIA; EFFECTS; IRON; LIVER; LIVER NEOPLASMS; DIAGNOSIS;
D O I
10.1002/jmri.1880040314
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AMI-25 was evaluated at 1.5 T as a superparamagnetic iron oxide contrast agent for the liver. Sixteen patients with up to five suspected focal liver lesions were examined with T1-, proton-density-, and T2-weighted spin-echo sequences before and after intravenous administration of AMI-25 (15 mumol/kg iron). The contrast-to-noise ratio (C/N) increased from 1.8 to 3.5 on 600/15 (TR msec/TE msec) images and from 1.7 to 7.9 on 2,500/15 images after AMI-25 administration (P < .01). C/N did not change significantly on 2.500/90 images. Two blinded readers counted the number of lesions visible on unenhanced and contrast-enhanced images, with the 32 sets of images of the 16 patients presented in random order. Both readers identified more lesions on AMI-25-enhanced images, but the difference was not statistically significant (P > .05). Two patients reported minor side effects (flushing, sensation of heat, lower back pain). On the basis of the results obtained in a limited number of patients, the authors conclude that at 1.5 T. AMI-25 does not significantly improve the detection of focal liver lesions on conventional spin-echo images.
引用
收藏
页码:309 / 314
页数:6
相关论文
共 50 条
  • [1] DETECTION OF FOCAL LIVER-LESIONS WITH SUPERPARAMAGNETIC IRON-OXIDE - VALUE OF STIR AND SE IMAGING
    HALAVAARA, JT
    LAMMINEN, AE
    BONDESTAM, S
    STANDERTSKJOLDNORDENSTAM, CG
    HAMBERG, LM
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (06) : 897 - 904
  • [2] The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide
    F. Deckers
    B. Corthouts
    Y. Nackaerts
    O. Ozsarlak
    P. M. Parizel
    A. M. De Schepper
    European Radiology, 1997, 7 : 887 - 892
  • [3] The influence of MR field strength on the detection of focal liver lesions with superparamagnetic iron oxide
    Deckers, F
    Corthouts, B
    Nackaerts, Y
    Ozsarlak, O
    Parizel, PM
    DeSchepper, AM
    EUROPEAN RADIOLOGY, 1997, 7 (06) : 887 - 892
  • [4] LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING
    BELLIN, MF
    ZAIM, S
    AUBERTON, E
    SARFATI, G
    DURON, JJ
    KHAYAT, D
    GRELLET, J
    RADIOLOGY, 1994, 193 (03) : 657 - 663
  • [5] IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER
    VANBEERS, B
    PRINGOT, J
    GALLEZ, B
    JOURNAL DE RADIOLOGIE, 1995, 76 (11): : 991 - 995
  • [6] CONTRAST-ENHANCED MR-IMAGING OF LIVER AND SPLEEN - 1ST EXPERIENCE IN HUMANS WITH A NEW SUPERPARAMAGNETIC IRON-OXIDE
    HAMM, B
    STAKS, T
    TAPUITZ, M
    MAIBAUER, R
    SPEIDEL, A
    HUPPERTZ, A
    FRENZEL, T
    LAWACZECK, R
    WOLF, KJ
    LANGE, L
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05): : 659 - 668
  • [7] CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS
    HAHN, PF
    STARK, DD
    WEISSLEDER, R
    ELIZONDO, G
    SAINI, S
    FERRUCCI, JT
    RADIOLOGY, 1990, 174 (02) : 361 - 366
  • [8] Focal hepatic lesions: Detection and characterization with combination gadolinium- and superparamagnetic iron oxide-enhanced MR imaging
    Kim, MJ
    Kim, JH
    Chung, JJ
    Park, MS
    Lim, LS
    Oh, YT
    RADIOLOGY, 2003, 228 (03) : 719 - 726
  • [9] Superparamagnetic iron oxide-enhanced versus gadolinium-enhanced MR imaging for differential diagnosis of focal liver lesions
    Vogl, TJ
    Hammerstingl, R
    Schwarz, W
    Mack, MG
    Muller, PK
    Pegios, W
    Keck, H
    EiblEibesfeldt, A
    Hoelzl, J
    Woessmer, B
    Bergman, C
    Felix, R
    RADIOLOGY, 1996, 198 (03) : 881 - 887
  • [10] FOCAL LIVER-LESIONS - CHARACTERIZATION WITH NONENHANCED AND DYNAMIC CONTRAST MATERIAL-ENHANCED MR-IMAGING
    HAMM, B
    THOENI, RF
    GOULD, RG
    BERNARDINO, ME
    LUNING, M
    SAINI, S
    MAHFOUZ, AE
    TAUPITZ, M
    WOLF, KJ
    RADIOLOGY, 1994, 190 (02) : 417 - 423