Determination of acrylamide in processed foods by column-switching HPLC with UV detection

被引:12
|
作者
Terada, H [1 ]
Tamura, Y [1 ]
机构
[1] Nagoya City Publ Hlth Res Inst, Mizuho Ku, Nagoya, Aichi 4678615, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2003年 / 44卷 / 06期
关键词
acrylamide; HPLC; column switching; aqueous gel permeation column; UV detector; processed food;
D O I
10.3358/shokueishi.44.303
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and convenient analytical method for the determination of acrylamide in processed foods was established. Acrylamide was extracted with water in an ultrasonic bath. The extract was passed through an OASIS HLB cartridge and the eluate was injected into the HPLC system using a column-switching technique. The HPLC system consisted of two pumps, two 6-port-2-position valves, two columns and a UV detector. At first, the sample solution was chromatographed on an ODS column with a mobile phase of water, then the flow of the mobile phase was switched using a 6-port-2-position valve, and the acrylamide peak fraction was introduced into an aqueous gel permeation column (analytical column). The fraction was chromatographed again on the analytical column with a mobile phase of water, and the eluate was monitored with a UV detector (205 nm). The recoveries of acrylamide from potato chips, fried potato, croquette and instant noodle fortified at levels of 50 to 1,000 mug/kg were 93.1 to 101.5% and the coefficient of variation was 1.5 to 5.2%. The detection limit corresponded to 10 mug/kg in processed foods. Forty-six samples, potato chips (11), fried potato (10), croquette (20) and instant noodle (5), were analyzed by this method. The acrylamide level was 67-4,499 mug/kg for potato chips, 1251,183 mug/kg for fried potato, nd-255 mug/kg for croquette and nd-151 mug/kg for instant noodle.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [31] Application of ion-trap LC/MS/MS for determination of acrylamide in processed foods
    Tsutsumiuchi, K
    Hibino, M
    Kambe, M
    Oishi, K
    Okada, M
    Miwa, J
    Taniguchi, H
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2004, 45 (02): : 95 - 99
  • [32] HPLC ANALYSIS OF SALINOMYCIN IN HUMAN PLASMA USING PRECOLUMN OXIDATION AND AUTOMATED HEART CUT COLUMN-SWITCHING
    KARNES, HT
    WEI, AT
    DIMENNA, GP
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (09) : 823 - 827
  • [33] Column-switching high-performance liquid chromatographic determination of clarithromycin in human plasma with electrochemical detection
    Choi, SJ
    Kim, SB
    Lee, HY
    Na, DH
    Yoon, YS
    Lee, SS
    Kim, JH
    Lee, KC
    Lee, HS
    TALANTA, 2001, 54 (02) : 377 - 382
  • [34] Simultaneous determination of uric acid and creatinine in biological fluids by column-switching liquid chromatography with ultraviolet detection
    Seki, T
    Yamaji, K
    Orita, Y
    Moriguchi, S
    Shinoda, A
    JOURNAL OF CHROMATOGRAPHY A, 1996, 730 (1-2) : 139 - 145
  • [35] Enantioselective determination of FCE 28833, a new potential antiischemic agent, in gerbil plasma using column switching HPLC with UV detection
    Breda, M
    Sarati, S
    Basileo, G
    Dostert, P
    CHIRALITY, 1997, 9 (02) : 133 - 138
  • [36] Occurrence, synthesis, toxicity and detection methods for acrylamide determination in processed foods with special reference to biosensors: A review
    Pundir, Chandra S.
    Yadav, Neelam
    Chhillar, Anil Kumar
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2019, 85 : 211 - 225
  • [37] Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection
    Brunetto, MR
    Cayama, YD
    García, LG
    Gallignani, M
    Obando, MA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) : 115 - 120
  • [38] Novel powder-XRD method for detection of acrylamide in processed foods
    Paranthaman, R.
    Moses, J. A.
    Anandharamakrishnan, C.
    FOOD RESEARCH INTERNATIONAL, 2022, 152
  • [39] SIMULTANEOUS DETERMINATION OF HUMAN NEUTROPHIL ELASTASE INHIBITOR (ONO-5046) AND ITS METABOLITE IN PLASMA AND URINE BY DIRECT-INJECTION COLUMN-SWITCHING HPLC
    SHINTANI, T
    TAKAMOTO, M
    SAWADA, M
    AISHITA, H
    NAKAGAWA, T
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (03) : 397 - 405
  • [40] Simultaneous determination of creatinine, hypoxanthine and uric acid in biological samples by column-switching liquid chromatography with ultraviolet detection
    Seki, T
    Orita, Y
    Yamaji, K
    Shinoda, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) : 1621 - 1626