Determination of acrylamide in processed foods by column-switching HPLC with UV detection

被引:12
|
作者
Terada, H [1 ]
Tamura, Y [1 ]
机构
[1] Nagoya City Publ Hlth Res Inst, Mizuho Ku, Nagoya, Aichi 4678615, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2003年 / 44卷 / 06期
关键词
acrylamide; HPLC; column switching; aqueous gel permeation column; UV detector; processed food;
D O I
10.3358/shokueishi.44.303
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and convenient analytical method for the determination of acrylamide in processed foods was established. Acrylamide was extracted with water in an ultrasonic bath. The extract was passed through an OASIS HLB cartridge and the eluate was injected into the HPLC system using a column-switching technique. The HPLC system consisted of two pumps, two 6-port-2-position valves, two columns and a UV detector. At first, the sample solution was chromatographed on an ODS column with a mobile phase of water, then the flow of the mobile phase was switched using a 6-port-2-position valve, and the acrylamide peak fraction was introduced into an aqueous gel permeation column (analytical column). The fraction was chromatographed again on the analytical column with a mobile phase of water, and the eluate was monitored with a UV detector (205 nm). The recoveries of acrylamide from potato chips, fried potato, croquette and instant noodle fortified at levels of 50 to 1,000 mug/kg were 93.1 to 101.5% and the coefficient of variation was 1.5 to 5.2%. The detection limit corresponded to 10 mug/kg in processed foods. Forty-six samples, potato chips (11), fried potato (10), croquette (20) and instant noodle (5), were analyzed by this method. The acrylamide level was 67-4,499 mug/kg for potato chips, 1251,183 mug/kg for fried potato, nd-255 mug/kg for croquette and nd-151 mug/kg for instant noodle.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [21] A sensitive column-switching HPLC method for aripiprazole and dehydroaripiprazole and its application to human pharmacokinetic studies
    Akamine, Yumiko
    Yasui-Furukori, Norio
    Kojima, Midori
    Inoue, Yoshimasa
    Uno, Tsukasa
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (21) : 3292 - 3298
  • [22] LC with Column-Switching and Spectrophotometric Detection for Determination of Risperidone and 9-Hydroxyrisperidone in Human Serum
    Katrin M. Kirschbaum
    Susann Finger
    Friederike Vogel
    Rainer Burger
    Manfred Gerlach
    Peter Riederer
    Christoph Hiemke
    Chromatographia, 2008, 67 : 321 - 324
  • [23] LC with column-switching and spectrophotometric detection for determination of risperidone and 9-hydroxyrisperidone in human serum
    Kirschbaum, Katrin M.
    Finger, Susann
    Vogel, Friederike
    Burger, Rainer
    Gerlach, Manfred
    Riederer, Peter
    Hiemke, Christoph
    CHROMATOGRAPHIA, 2008, 67 (3-4) : 321 - 324
  • [24] LC-UV Column-Switching for Quantitation of Vitamin K1 in Infant Formula
    Ko, Jinhyouk
    Kwak, Byung-Man
    Ahn, Jang-Hyuk
    Jeong, Seung-Hwan
    Shim, Sung-Lye
    Kim, Kyong-Su
    Yoon, Taehyung
    Dong-gil, Leem
    Jeong, Jayoung
    CHROMATOGRAPHIA, 2010, 72 (7-8) : 665 - 670
  • [25] Determination of a potent urokinase-type plasminogen activator, UK-356,202, in plasma at pg/mL levels using column-switching HPLC and fluorescence detection
    Bayliss, Mark A. J.
    Venn, Richard F.
    Edgington, Alan M.
    Webster, Robert
    Walker, Donald K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 121 - 126
  • [26] HPLC column-switching technique for sample preparation and fluorescence determination of propranolol in urine using fused-core columns in both dimensions
    Satinsky, Dalibor
    Havlikova, Lucie
    Solich, Petr
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (20) : 6583 - 6587
  • [27] Determination of sparteine in human serum by column-switching HPLC with electrogenerated chemiluminescence detection using tris(2,2′-bipyridine)ruthenium(II)
    Uchikura, K
    Satou, N
    BUNSEKI KAGAKU, 2003, 52 (08) : 641 - 645
  • [28] HPLC column-switching technique for sample preparation and fluorescence determination of propranolol in urine using fused-core columns in both dimensions
    Dalibor Šatínský
    Lucie Havlíková
    Petr Solich
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6583 - 6587
  • [29] Development of a Fully-automated On-line Oxidation Column-switching HPLC System for the Determination of Endogenous Melatonin in Human Clinical Samples
    Tsubasa Oyama
    Rie Nagai
    Mayumi Fujimoto
    Ryoko Konishi
    Masashi Mita
    Keiko Uezono
    Kiyoshi Zaitsu
    Kenji Hamase
    Analytical Sciences, 2015, 31 : 1129 - 1135
  • [30] Development of a Fully-automated On-line Oxidation Column-switching HPLC System for the Determination of Endogenous Melatonin in Human Clinical Samples
    Oyama, Tsubasa
    Nagai, Rie
    Fujimoto, Mayumi
    Konishi, Ryoko
    Mita, Masashi
    Uezono, Keiko
    Zaitsu, Kiyoshi
    Hamase, Kenji
    ANALYTICAL SCIENCES, 2015, 31 (11) : 1129 - 1135