Determination of acrylamide in processed foods by column-switching HPLC with UV detection

被引:12
|
作者
Terada, H [1 ]
Tamura, Y [1 ]
机构
[1] Nagoya City Publ Hlth Res Inst, Mizuho Ku, Nagoya, Aichi 4678615, Japan
来源
JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN | 2003年 / 44卷 / 06期
关键词
acrylamide; HPLC; column switching; aqueous gel permeation column; UV detector; processed food;
D O I
10.3358/shokueishi.44.303
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A simple and convenient analytical method for the determination of acrylamide in processed foods was established. Acrylamide was extracted with water in an ultrasonic bath. The extract was passed through an OASIS HLB cartridge and the eluate was injected into the HPLC system using a column-switching technique. The HPLC system consisted of two pumps, two 6-port-2-position valves, two columns and a UV detector. At first, the sample solution was chromatographed on an ODS column with a mobile phase of water, then the flow of the mobile phase was switched using a 6-port-2-position valve, and the acrylamide peak fraction was introduced into an aqueous gel permeation column (analytical column). The fraction was chromatographed again on the analytical column with a mobile phase of water, and the eluate was monitored with a UV detector (205 nm). The recoveries of acrylamide from potato chips, fried potato, croquette and instant noodle fortified at levels of 50 to 1,000 mug/kg were 93.1 to 101.5% and the coefficient of variation was 1.5 to 5.2%. The detection limit corresponded to 10 mug/kg in processed foods. Forty-six samples, potato chips (11), fried potato (10), croquette (20) and instant noodle (5), were analyzed by this method. The acrylamide level was 67-4,499 mug/kg for potato chips, 1251,183 mug/kg for fried potato, nd-255 mug/kg for croquette and nd-151 mug/kg for instant noodle.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 50 条
  • [1] Determination of simvastatin in human plasma by column-switching HPLC with UV detection
    Kim, BC
    Ban, E
    Park, JS
    Song, YK
    Kim, CK
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2004, 27 (19) : 3089 - 3102
  • [2] Determination of acrylamide in processed foods by LC/MS using column switching
    Takatsuki, S
    Nemoto, S
    Sasaki, K
    Maitani, T
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2003, 44 (02): : 89 - 95
  • [3] DETERMINATION OF TRIAMTERENE IN URINE BY HPLC USING FLUORESCENCE DETECTION AND COLUMN-SWITCHING
    FALCO, PC
    HERRAEZHERNANDEZ, R
    SEVILLANOCABEZA, A
    CHROMATOGRAPHIA, 1994, 38 (1-2) : 29 - 34
  • [4] FULL AUTOMATION OF SEROTONIN DETERMINATION BY COLUMN-SWITCHING AND HPLC
    GROSSI, G
    BARGOSSI, A
    SPROVIERI, G
    BERNAGOZZI, V
    PASQUALI, R
    CHROMATOGRAPHIA, 1990, 30 (1-2) : 61 - 68
  • [5] Determination of the antifungal agent posaconazole in human serum by HPLC with parallel column-switching technique
    Neubauer, Werner
    Koenig, Armin
    Bolek, Richard
    Trittler, Rainer
    Engelhardt, Monika
    Jung, Manfred
    Kuemmerer, Klaus
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (24): : 2493 - 2498
  • [6] SIMULTANEOUS DETERMINATION OF IBUPROXAM AND IBUPROFEN IN HUMAN PLASMA BY HPLC WITH COLUMN-SWITCHING
    JUNG, ES
    LEE, HS
    RHO, JK
    KWON, KI
    CHROMATOGRAPHIA, 1993, 37 (11-12) : 618 - 622
  • [7] Determination of propofol in human serum by HPLC using a semi-micro bore column and a column-switching technique
    Hashimoto, Y
    Chiba, R
    Kobayashi, Y
    Moriyama, H
    Matsumoto, Y
    Tanaka, A
    Matsumoto, M
    BUNSEKI KAGAKU, 1997, 46 (04) : 301 - 305
  • [8] Improved HPLC column-switching determination of coenzyme Q and Vitamin E in plasma
    Bompadre, Stefano
    Tulipani, Sara
    Romandini, Stefania
    Giorgetti, Raffaele
    Battino, Maurizio
    BIOFACTORS, 2008, 32 (1-4) : 257 - 262
  • [9] Direct determination of stability of protease inhibitors in plasma by HPLC with automated column-switching
    Peng, SX
    Strojnowski, MJ
    Bornes, DM
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (3-4) : 343 - 349
  • [10] Determination of the active metabolites of sibutramine in rat serum using column-switching HPLC
    Um, So Young
    Kim, Kyu-Bong
    Kim, Seon Hwa
    Ju, Young Cheol
    Lee, Hye Sang
    Oh, Hye Young
    Choi, Ki Hwan
    Chung, Myeon Woo
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (15) : 2820 - 2826