AN EFFICIENT SINGLE-CRYSTAL BSE DETECTOR IN SEM

被引:33
|
作者
AUTRATA, R [1 ]
HERMANN, R [1 ]
MULLER, M [1 ]
机构
[1] INST CELL BIOL,LAB EMI,ZURICH,SWITZERLAND
关键词
D O I
10.1002/sca.4950140302
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Using the optical modifications described, the signal of the wide-angle BSE detector can be increased 3.7-fold compared with the detector type illustrated in Figure 1. The increase was achieved by more fully exploiting the optical phenomena of diffusion, reflection at the critical angle and antireflection, and especially that of their combined effects. A higher photon energy transfer was obtained by specific optical modifications to the scintillator and the light guide. Based on the current modifications, it can be estimated that about 75% of the generated light reaches the PMT. It is necessary, therefore, to revise all values previously published of the DQE coefficient of the YAG scintillator. A general value of DQE is of verv limited use depending as it does on the specific conditions under which light emerges from the YAG scintillator. The DQE, therefore, does not permit sufficiently accurate comparison with other scintillation materials. The DQE can be evaluated only for a completed detector configuration in which the laws of geometrical optics apply, or it can be used for making comparisons of scintillation materials used in the same detector configuration.
引用
收藏
页码:127 / 135
页数:9
相关论文
共 50 条
  • [31] TIME OF FLIGHT SINGLE-CRYSTAL DIFFRACTOMETER USING A POSITION-SENSITIVE DETECTOR
    NIIMURA, N
    KUBOTA, T
    SATO, M
    ARAI, M
    ISHIKAWA, Y
    NUCLEAR INSTRUMENTS & METHODS, 1980, 173 (03): : 517 - 523
  • [32] Optimization and planning of experiments in single-crystal diffractometry with a zero-dimensional detector
    Nekrasov, Y
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2001, 34 : 386 - 387
  • [33] Single-crystal CVD diamond detector for high-resolution particle spectrometry
    Sato, Y.
    Murakami, H.
    Shimaoka, T.
    Tsubota, M.
    Kaneko, J. H.
    EPL, 2014, 108 (04)
  • [34] ENERGY RESOLUTION OF SCINTILLATION DETECTOR WITH NAI(T1) SINGLE-CRYSTAL
    PERKOV, AI
    FEDOTOV, SN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1988, 31 (03) : 590 - 592
  • [35] On the application of a single-crystal κ-diffractometer and a CCD area detector for studies of thin films
    Sonsteby, Henrik Hovde
    Chernyshov, Dmitry
    Getz, Michael
    Nilsen, Ola
    Fjellvag, Helmer
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 644 - 647
  • [36] INFRARED DETECTOR SYSTEM FOR POLARIZED SINGLE-CRYSTAL ABSORPTION-SPECTRA WITH A MICROSPECTROPHOTOMETER
    ZELANO, JA
    SIGOUNTOS, JG
    MAKINEN, MW
    SANDERS, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1985, 56 (03): : 398 - 401
  • [37] A two-detector single-crystal scintillation autocorrelation spectrometer with rejection of afterpulses
    Morozov, VA
    Morozova, NV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2003, 46 (01) : 32 - 34
  • [38] A two-detector single-crystal scintillation autocorrelation spectrometer with rejection of afterpulses
    Morozov, V.A.
    Morozova, N.V.
    Pribory i Tekhnika Eksperimenta, 2003, 46 (01): : 37 - 39
  • [39] Evaluation of a synthetic single-crystal diamond detector for relative dosimetry measurements on a CyberKnife™
    Chalkley, A.
    Heyes, G.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1035):
  • [40] A Study of the Fast Neutron Response of a Single-Crystal Diamond Detector at High Temperatures
    Kumar, Amit
    Topkar, Anita
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2018, 65 (01) : 630 - 635