COMPARISON OF DISPAROMETER FIXATION DISPARITY CURVES AS MEASURED WITH AND WITHOUT THE PHOROPTER

被引:6
作者
FRANTZ, KA [1 ]
SCHARRE, JE [1 ]
机构
[1] ILLINOIS COLL OPTOMETRY,CHICAGO,IL
关键词
Associated phoria; Disparometer; Examination procedures; Fixation disparity; Fixation disparity curve; Phoropter;
D O I
10.1097/00006324-199002000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Traditionally, Disparometer fixation disparity curve (FDC) measurement has been performed using a phoropter, although more recently some clinicians have suggested that the Disparometer be used outside the phoropter. Whereas vertical fixation disparity (FD) measurements have been found to correlate well when obtained with and without a phoropter, there is currently no evidence that horizontal FDC’s are similar in the two testing situations. A FDC was plotted for 30 visually asymptomatic young adults both in and out of the phoropter. Statistical analysis revealed no significant differences between results on the basis of curve type, slope, y- or x-intercept; however, noteworthy individual variations did occur. Therefore, we conclude that consistency of testing method is important when serial curves are plotted for a given patient. Although each method has some advantages and disadvantages, neither is clearly superior based on this study. © 1990 American Academy of Optometry.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 20 条
[1]  
Sheedy J.E., Fixation disparity analysis of oculomotor imbalance, Am J Optom Physiol Opt, 57, pp. 632-639, (1980)
[2]  
Daum K.M., The stability of the fixation disparity curve, Ophthal Physiol Opt, 3, pp. 13-19, (1983)
[3]  
Wick B., Forced vergence fixation disparity curves at distance and near in an asymptomatic young adult population, Am J Optom Physiol Opt, 62, pp. 591-599, (1985)
[4]  
Ancri O., McMahon C., Keller P., Stability of fixation disparity and associated measures as a function of time of day, Clin Exp Optom, 69, pp. 13-15, (1986)
[5]  
Garzia R.P., Dyer G., Effect of nearpoint stress on the horizontal forced vergence fixation disparity curve, Am J Optom Physiol Opt, 63, pp. 901-907, (1986)
[6]  
Brownlee G.A., Goss D.A., Comparison of commercially available devices for the measurement of fixation disparity and associated phorias, J am Optom Assoc, 59, pp. 451-460, (1988)
[7]  
Wesson M.D., A new clinical method for direct measurement of fixation disparity, South J Optom, 1, pp. 48-52, (1983)
[8]  
Saladin J.J., Convergence insufficiency, fixation disparity and control systems analysis, Am J Optom Physiol Opt, 63, pp. 645-653, (1986)
[9]  
Saladin J.J., Sheedy J.E., Population study of fixation disparity, heterophoria, and vergence, Am J Optom Physiol Opt, 55, pp. 744-750, (1978)
[10]  
London R., Fixation disparity and heterophoria, Ocular Assessment. Boston: Butterworths, (1984)